× All the transactions performed on 2.0 is available here. To access Market click "Home".

electrolyte analyzer (diamond diagnostics)(prolyte)

` 105,000.00

  • MRP: `135000.00

Whole Blood, Serum, Plasma or UrineSample Size100 l Whole Blood, Serum or PlasmaNumber of Parameters3 SimultaneouslyReproducibilityTypical Within Run n30Blood, Serum, PlasmaNa CV 1 115-160mmol/LK CV 2 2.5-6 mmol/LCl- CV 2 65-120 mmol/LUrineNa CV 5 60-280 mmol/LK CV 5 30-170 mmol/LCl- CV 5 80-230 mmol/LLi SD 0.03 0.25-2.0 mmol/LDisplay ResolutionNa 1 mmol/LK 0.1 mmol/LCl- 1 mmol/LLi 0.01 mmol/LAnalysis Time57 sec Blood93 sec UrineData Storage1000 Patient Results500 Level 1 QC Results500 Level 2 QC Results500 Level 3 QC ResultsCalibration2 Point every 4 hoursOn DemandUser InputKeypad, External KeyboardExternal Barcode Scanner optionalOutputGraphic backlit displayGraphic 40 column printerRS232 LIS CommunicationDetection Range 45-205 mmol/L 1.5-11 mmol/L 45-205 mmol/L 0.15-5.0 mmol/L 30-1020 mmol/L 20-505 mmol/LBlood Na KClLiUrine NaKCl- 25-505 mmol/L.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Ignition System - Auto ignition
  • Analyzed Elements - Na+, Ca++, K+, Li+
  • Accuracy - Less than +- 2 %
  • Sensitivity - Na+ = 1 ppm, Ca++ = 15 ppm, K+ = 1 ppm, Li+ = 1 ppm
  • Filters - Sodium, Potassium, Calcium, Lithium
Other Specifications Download Specification
System Is Capable To Measure Alkali And Alkaline Earth Metals (Sodium, Potassium, Calcium, Lithium) In The Samples Yes
Ignition System Auto ignition
Analyzed Elements Na+, Ca++, K+, Li+
Accuracy Less than +- 2 %
Reproducibility Less than +- 2 %
Sensitivity Na+ = 1 ppm, Ca++ = 15 ppm, K+ = 1 ppm, Li+ = 1 ppm
Display at least 3 lines LCD
Detector Photo conductive cell
Filters Sodium, Potassium, Calcium, Lithium
Aspiration Rate 3 to 6 ml/min
Memory To store and recall 800 samples
Type Of Printer Interface For Printing Of Samples Thermal
Accessories Compressor with built in air regulator and air filter
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " Yes
Power Requirements 230 V +- 10, 50 Hz AC
Operating Temperature 15-32 Degree C
Operating Humidity (RH) < 85 %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" yes
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) yes
Test Report No. 02014
Test Report Date 24.08.2017
Name Of The Lab Central Lab
Warranty 1 Year

Price Dekho Price Dekho Price List in india