× All the transactions performed on 2.0 is available here. To access Market click "Home".

regnaults apparatus for specific heat by mixtures (accurate)(asirash)

` 3,420.00

  • MRP: `3800.00

A Steam Bath Is Used To Heat The Solid Of Unknown Specific Heat By Suspending It Inside The Inner Compartment Whose Temperature Can Be Measured Accurately. The Heating Part Is Separated From The Calorimeter By A Sliding Baffle That Isolates It From Heat Gain From Its Influence. The Calorimeter Vessel Is Well Insulated And Can Be Slid Under The Heater By Opening The Baffle. The Heated Solid Can Be Quickly Dropped Into The Calorimeter That Is Then Slid Back To The Other End Of The Apparatus, The Baffle Lowered And The Heat Rise Of The Calorimeter Noted. The Necessary Cooling Corrections Are Made For Heat Loss From The Calorimeter. The Construction Of The Apparatus Enables The Transfer Of The Solid Without Significant Heat Loss And Errors Due To Heat Gain From External Sources...

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 12
  • DC Current Output Rating - 0 to 4 Ampere
  • Maximum Power - 120 Watt
  • Load Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 2 mV
  • Line Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 1 mV
  • Over Voltage Protection Response Time - less than 10 milli sec
Other Specifications Download Specification
DC Voltage Output Rating 0 to 30 Volt
DC Current Output Rating 0 to 4 Ampere
Maximum Power 120 Watt
Load Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 2 mV
Load Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 1.5 mA
Line Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 1 mV
Line Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 0.1 mA
Over Voltage Protection Accuracy +- 0.5 + 0.5 V
Over Voltage Protection Response Time less than 10 milli sec
Ripple And Noise Voltage (20 Hz To 20 MHz) less than 1 mVrms less than 4 mVpp
Ripple And Noise Current (20 Hz To 20 MHz) less than 4 mArms
Readback Voltage Accuracy 0.05 + 10 mV
Readback Current Accuracy 0.15 + 4 mA
Readback Voltage Resolution 1 mV
Readback Current Resolution 0.1 mA
Operating Temperature 0-50 Degree C
Gperating Humidity (RH) N/A %
PC Interface USB
Dimensions N/A mm x mm x
Weight GPIB gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. N/A
Test Report Date N/A
Name Of The Lab N/A
Warranty 1 Year

Price Dekho Price Dekho Price List in india