A portable filtration machine for transformer oil with flow rate of 1000 LPH...
Other Specifications Download Specification | |
---|---|
Mode Of Working | Offline |
Type | Portable |
Type Of Oil For Which Machine Is To Be Used For Cleaning | Transformer Oil |
Type Of Cleaning | Removal of Both Soild Contamination and Liquid Contamination |
Nominal Flow Rate | 1000 LPH |
Centrifuge Pump Flow Rate | 16 LPM |
Centrifuge Motor Capacity | 0.5 HP |
Centrifuge Make Of Motor | others Confirming to IS 325:1996 reaffirmed 2007 with ISI Marked |
Suction Pump Flow Rate | 30 LPM |
Suction Pump Motor Capacity | 1 HP |
Make Of Motor(Suction Pump) | others Confirming to IS 325:1996 reaffirmed 2007 with ISI Marked |
Discharge Pump Flow Rate | 30 LPM |
Discharge Pump Motor Capacity | 1 HP |
Make Of Motor( Discharge Pump) | others Confirming to IS 325:1996 reaffirmed 2007 with ISI Marked |
Dirt Holding Capacity | 500 grams |
Dirt Holding Capacity( For Others) | NA grams |
Minimum Size Of Dirt( Including Metallic ,Non Metallic ,Suspended Soild Particle ) | 5 micron |
Length Of Inlet Wire Braided Hose Pipe | 5000 mm |
Diameter Of Inlet Wire Braided Hose Pipe | 19 mm |
Length Of Outlet Wire Braided Hose Pipe | 5000 mm |
Diameter Of Outlet Wire Braided Hose Pipe | 19 mm |
Vacuum Pump For First Stage | Yes |
Vacuum Pump For Second Stage | No |
Vacuum Pump Motor Capacity ( For First Stage ) | 0.5 HP |
Vacuum Pump Motor Capacity ( For Second Stage ) | NA HP |
Vacuum Booster For First Stage | No |
Vacuum Booster For Second Stage | No |
Vacuum Booster Motor Capacity ( For First Stage ) | NA HP |
Vacuum Booster Motor Capacity ( For Second Stage ) | NA HP |
Vacuum Blower | No |
Vacuum Blower Motor Capacity | NA hp |
Moisture Separator | Yes |
If Yes Then Moisture Separating Capacity (otherwise Put NA) | 150 ml |
Moisture Seperator Capacity (for Others ) | NA ml |
Operating Pressure ,Max | 5 Bar |
Operating Temperature | 60 Degree Celcius |
Heating System | Yes |
Heater Capacity | 12 kw |
Degassing Chamber | Yes |
Dimensions Of Degassing Chamber (Diameter X Height) | 400X1100 apx mm x mm |
Capacity Of Degassing Chamber | 175 apx ltrs |
Ionic Reaction Cartridge | No |
Oil Reclamation Cartridge | No |
Water Adsorption Cartridge | No |
Filter Cartridge ( For Solid Contamination Removal Only) | Consumable |
Magnetic Strainer | Yes |
Length Of The Centrifugal Oil Cleaning Machine | 1000 apx mm |
Width Of The CentrifugalOil Cleaning Machine | 500 apx mm |
Height Of The Centrifugal Oil Cleaning Machine | 800 apx mm |
Weight Of The Centrifugal Oil Cleaning Machine | 800 apx Kg |
Make Of Control Panel (All Parts) | Others Confirming to IS |
Dimensions Of Panel Box Confirming To IS 10322/1982Reaffirmed 2005( Length X Width X Height ) | others mm x mm x mm |
If Others Then Specify The Dimensions In LxWx H) | 400X300X450 apx mm x mm x mm |
Thickness Of Panel Box Confirming To IS 10322/1982Reaffirmed 2005 | 300 apx mm |
Online Moisture PPM Sensor | No |
Tramp Oil Skimmer | No |
Flowmeter | Yes |
Voltmeter (0-500 V) With Inbuilt Selector Switch | Yes |
Control Transformer | Yes |
Ammeter Digital 0-20 Amps | Yes |
Hours Counter Meter | Yes |
Indicator Light 3-ph | Yes |
No. Of Push Button | 8 |
Legent Plate 3mm Thick | Yes |
MCB TP 10-32 Amp | Yes |
MCB SP 2- Amp For Volt/Cont | Yes |
12 Amp Contactor 3 Pole | Yes |
O/L Relay 4-6.5 Amp | Yes |
Terminal Block 2.5 Mm | Yes |
Protection Relay Model -VSP-D1 | Yes |
Over Load Trip Indication 22.5 Mm Dia | Yes |
PVC Gland 13.5 /16x4x1.5 Mm | Yes |
Cable 4Cx 1.5 Mm(5 Meter) | Yes |
Machine Enclosure | Open Type |
Machine Wheels | Castor |
Lsit Of Standards Accessories Of Panel Box With Numbers To Be Provided | Indicator Light 3 phase - 3 Nos. Volt meter - 1 Nos. Amp. meter - 1 Nos. Hour Counter - 1 Nos. Push Button - 4 Nos. MCB TP 32 Amp - 1 Nos. MCB SP 6 Amp - 3 Nos. Contractor - 12 Amp 3 pole 2 Nos. O/L Relay - 2.5-4 Amp - 2 Nos. Protection relay - VSP- D-1 Cable Wire - 4C X 1.5mm2 |
Availability Of Test Report From Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification | Yes |
Test Report No. | K/14365 |
Test Report Date | 13-May-2014 |
Name Of The Lab | Sigma Test & Research Centre |
Address Of The Lab | Delhi |