× All the transactions performed on 2.0 is available here. To access Market click "Home".

Multiparameter pH Meter - pH, ORP, Conductivity, TDS, Salinity, Resistivity, Temperature (LABMAN)(LMMP-30 UP)

` 32,794.00

  • Offered Price: ` 34520.00
  • MRP: `49000.00

pH Range -2.000 to 20.000 pH, Resolution 0.001, 0.01, 0.1pH, Selectable, Accuracy 0.002 pH, Calibration Points Up to 5 points, ORP 0 - 1999.9 mV, Resolution 0.1, /1mV, Selectable, Accuracy 0.2mV, Conductivity Range 0-200 mS/cm, Accuracy 0.5 percentage Full Scale, Cell Constant 0.1/1/10/User defined, TDS Range 0-10ppt, TDS Resolution 0.01/0.1/1, TDS Accuracy 1 percentage Full Scale, Salinity Range 0-80ppt, Salinity Resolution 0.01/0.1/1, Salinity Accuracy 1 percentage Full Scale, Resistivity Range 0-100MOM, Resistivity Resolution 1/0.1/0.01, Resistivity Accuracy 1 percentage Full Scale, Temp. Range 0-105 deg.C, Temp. Compensation 0-100 deg.C Auto or Manual, Auto-Off Function, Reset and Auto Hold Function, Electrode Diagnosis Slope, Offset, Stability Conditions High or Low, Selectable, Calibration due reminder, Memory 500 data sets with Date/Time, Output Connector USB Communication Interface and BNC / 6-pin connector.

  • Availability: 3 In Stock
  • Min. Qty. Per Consignee: 1
  • pH Range - 0.00 to 14.00 pH
  • Resolution - 0.01 pH
  • Accuracy - +- 0.05 pH
  • Modes - pH mV- C
  • Temperature Compensation Range - 0 to 100 Degree C
Other Specifications Download Specification
Type Microprocessor Based
PH Range 0.00 to 14.00 pH
Resolution 0.01 pH
Accuracy +- 0.05 pH
Calibration up to 3 points with auto buffer
Modes pH mV- C
Display LED / LCD / Touch Screen, 3 digits
Temperature Compensation Type Automatic
Temperature Compensation Range 0 to 100 Degree C
Temperature Accuracy +- 0.3 Degree C
Parallel Temperature Indication Yes
Storage Pocket For PH Electrode Yes
System To Be Supplied With Measuring Electrode Combined (glass Calomel), Temperature Probe, Electrode Stand, Calibration Buffer And Maintenance Kit, Operation Manual, Power Cable And Plug. Yes
Ingress Protection (Water Tight) 21
Impact Resistant Yes
Corrosion Resistant Yes
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " Yes
Power Requirements 230 V +- 10, 50 Hz AC
Operating Temperature 32 Degree C
Operating Humidity (RH) 50 %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer) As per OEM
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) As per OEM
Test Report No. As per OEM
Test Report Date As per OEM
Name Of The Lab As per OEM
Warranty 1 Year

Price Dekho Price Dekho Price List in india