Features Pre-Amplifier. Field Strength Measurement capability . AM/FM/SSB Analysis. 6 dB EMI Bandwidth/ QP Detection. Frequency counter 1mHz Resolution. USB Interface. Field-proven design Three-hour battery life, rugged, compact, lightweight, daylight viewable display. Intuitive menu-driven touchscreen user interface. Standard three-year warranty battery one-year warranty. Measurements Occupied Bandwidth, Channel Power, ACPR, C/I, Spectral Emission Mask . Dynamic Range 102 dB in 1 Hz RBW. DANL - 162 dBm in 1 Hz RBW. Phase Noise - 100 dBc/Hz max @ 10 kHz offset at 1 GHz. Save-on- Event . 2000 Traces and setups can be stored internally. Accessories included with Instrument Soft Carrying Case, CD for Handheld Instruments Documentation Anritsu Software Tool Box, Touchscreen Protective Film, Stylus with Coiled Tether, AC/DC Power Supply, Li-Ion Battery, Automotive Power Adapter , USB A-mini B Cable, Certificate of Calibration and Conformance..
Other Specifications Download Specification | |
---|---|
Description Of The Item | Spectrum analyzers 3GHz |
Frequency Range | 9 kHz to 3 GHz |
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year | Yes |
Frequency Counter Resolution(min.) | 1 Hz |
Frequency Span | 0Hz(zero span),1kHz to 3GHz |
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz | Yes |
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc | Yes |
Sweep Time @span >or= 1 KHz | 0.1S to 1000 s |
Sweep Time @span = 0 Hz | 100 micro S to 20 S |
Resolution Bandwidth (-3dB) | 100 Hz to 3 MHz in steps |
Video Bandwidth | 30 Hz to 1 MHz in steps |
Amplitude : Max Input Level For Protection | +30 dBm |
Amplitude : Max Input Level For Measurement | +20 dBm |
Amplitude :level Measurement Uncertainity | <or=2 dB |
Average Noise Level Displayed | 300HzRBW,10Hz VBW: |
Markers | Normal and delta |
Trigger | Free run, video, External |
Display | TFT Colour display |
Interface | USB |
Measurement Features | CN ratio,AM,time domain power measurement,channel power measurement,Phase noise measurement,TOI,OBW |
Software For Transfer Of Screen Shot/measurement Data To PC | Yes |
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. | NA |
Frequency Range For 2port Vector Network Analyzer | 2 MHz to 3 GHz |
Frequency Resolution (CW ON) For 2port Vector Network Analyzer | NA Hz |
Return Loss For 2port Vector Network Analyzer | NA dB |
VSWR For 2port Vector Network Analyzer | NA |
Cable Loss For 2port Vector Network Analyzer | NA dB |
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB | NA |
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible | NA |
Phase Range For 2port Vector Network Analyzer | NA degree |
Phase Resolution For 2port Vector Network Analyzer | NA deg |
RF Output Port For 2port Vector Network Analyzer | Type N, female, 50Ohm |
Dynamic Range For 2port Vector Network Analyzer | NA dB |
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. | NA |
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible | NA |
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available | NA |
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared | NA |
Operating Temperature | 5 to 40 degree C & 80 RH 40 degree C |
Power Requirement | 230 +- 10 VAC, 50Hz |
Warranty | 3 years |
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works | yes |
One Set Of Operation And Maintenance Manual Shall Be Supplied | yes |
Standard Accessories Shall Be Supplied | yes |
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications | yes |
Test Report No | Yes |
Test Report Date | Yes |
Name Of Lab | Anritsu Company |
Address Of The Lab | 490, Jarvis Drive, Morgan Hill, CA, 95037 USA |