Features - Two-active-port, fully-reversing VNA, Measures all four S-parameters with a single connection. 3-receiver architecture for higher measuring speed, 12-term error correction algorithm. User-configured 4-quadrant display for up to four S-parameters. Supports waveguide measurements, and SOLT, SSLT and SST calibrations. New Polar Impedance display. Transmission Dynamic Range 2 MHz to 3 GHz100 dB, 3 to 6 GHz 90 dB, 6GHz 85 dB. 350 sec per data point sweep speed, ideal for fast filter tuning. Store more than 13,000 traces and setups in memory . High resolution daylight viewable TFT color display. Built-in editable Cable and Signal Standard List. Options - MS2028C - VNA Master, 2-port, 5 kHz - 20 GHz Qty 1, MS2028C-0015 - Option 15, Vector Voltmeter Qty 1, TOSLNF50A-18 - Coaxial Calibration Kit, Type Nf, DC to 18 GHz, 50 Qty 1, 15NN50-1.0B - Test Port Extension Cable, Armored, Phase Stable, 1.0 meter, DC to 18 GHz, Nm - Nm, 50 Qty -2..
Other Specifications Download Specification | |
---|---|
Description Of The Item | Two port vector network analyzers 6GHz(without spectrum analyser) |
Frequency Range | NA |
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year | NA |
Frequency Counter Resolution(min.) | NA Hz |
Frequency Span | NA |
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz | NA |
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc | NA |
Sweep Time @span >or= 1 KHz | NA |
Sweep Time @span = 0 Hz | NA |
Resolution Bandwidth (-3dB) | NA |
Video Bandwidth | NA |
Amplitude : Max Input Level For Protection | NA dBm |
Amplitude : Max Input Level For Measurement | NA dBm |
Amplitude :level Measurement Uncertainity | NA dB |
Average Noise Level Displayed | NA |
Markers | NA |
Trigger | NA |
Display | TFT Colour display |
Interface | USB and LAN |
Measurement Features | NA |
Software For Transfer Of Screen Shot/measurement Data To PC | Yes |
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. | Yes |
Frequency Range For 2port Vector Network Analyzer | 2 MHz to 6 GHz |
Frequency Resolution (CW ON) For 2port Vector Network Analyzer | 10 Hz |
Return Loss For 2port Vector Network Analyzer | 0.00 to 60 dB |
VSWR For 2port Vector Network Analyzer | 1.01 to 10.00 |
Cable Loss For 2port Vector Network Analyzer | 0.00 to 30.00 dB |
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB | Yes |
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible | Yes |
Phase Range For 2port Vector Network Analyzer | -180 to +180 degree |
Phase Resolution For 2port Vector Network Analyzer | 0.01 deg |
RF Output Port For 2port Vector Network Analyzer | Type N, female, 50Ohm |
Dynamic Range For 2port Vector Network Analyzer | 60 dB |
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. | High Port Power (dBm): 5 kHz to 3 GHz=+3, > 3 GHz to 20 GHz= -3 Low Port Power (dBm): 5 kHz to 6 GHz=-25, > 6 GHz to 20 GHz=-15 |
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible | Yes |
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available | Yes |
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared | Yes, Less than 180 degree of phase change within the aperture |
Operating Temperature | 5 to 40 degree C & 80 RH 40 degree C |
Power Requirement | 230 +- 10 VAC, 50Hz |
Warranty | 3 years |
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works | yes |
One Set Of Operation And Maintenance Manual Shall Be Supplied | yes |
Standard Accessories Shall Be Supplied | yes |
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications | yes |
Test Report No | Yes |
Test Report Date | Yes |
Name Of Lab | Anritsu Company |
Address Of The Lab | 490, Jarvis Drive, Morgan Hill, CA 95037 USA |