× All the transactions performed on 2.0 is available here. To access Market click "Home".

20 GHz VNA Microwave Site Master - S820E (Anritsu)(S820E, Options S820E-0720, S820E-0440, 15KKF50-10A-2ea, TOSLKF50A-20)

` 1,788,000.00

  • MRP: `2352600.00

Features - 110 dB of dynamic range from 20 MHz to 8 GHz,105 db of Dynamic range from 8Ghz to 40 Ghz, 650 s/data point for fast field measurements. 1-port measurements Return Loss, VSWR, Cable Loss, Distance-To-Fault, Smith Chart, 1-port phase. 2-port measurements Transmission Measurement and Swept Cable Loss. 8.4 inch touchscreen with daylight/nighttime viewable modes. Explosive Atmosphere MIL-PRF-28800F Section 4.5.6.3 compliant. Fully reversing sweep, Simultaneous measurement of all 4 S-Parameters for a 2 port device. User configurable quad display in 1,2,3 or 4 display trace format with any combination of trace overlays. Large selection of graph types, including Real Impedance and Imaginary Impedance. Reference plane extension both ports feature also allows compensation for loss. Interpolation user selectable on/off reduces need to re-calibrate..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Frequency Range - NA
  • Aging rate of spectrum analyzer frequency: Better than 1x10-6 /Year - NA
  • Frequency counter Resolution(min.) - NA Hz
  • Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz - NA
  • Sweep time @span = 0 Hz - NA
Other Specifications Download Specification
Description Of The Item Two port vector network analyzers 6GHz(without spectrum analyser)
Frequency Range NA
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year NA
Frequency Counter Resolution(min.) NA Hz
Frequency Span NA
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz NA
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc NA
Sweep Time @span >or= 1 KHz NA
Sweep Time @span = 0 Hz NA
Resolution Bandwidth (-3dB) NA
Video Bandwidth NA
Amplitude : Max Input Level For Protection NA dBm
Amplitude : Max Input Level For Measurement NA dBm
Amplitude :level Measurement Uncertainity NA dB
Average Noise Level Displayed NA
Markers NA
Trigger NA
Display TFT Colour display
Interface USB and LAN
Measurement Features NA
Software For Transfer Of Screen Shot/measurement Data To PC Yes
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. Yes
Frequency Range For 2port Vector Network Analyzer 2 MHz to 6 GHz
Frequency Resolution (CW ON) For 2port Vector Network Analyzer 10 Hz
Return Loss For 2port Vector Network Analyzer 0.00 to 60 dB
VSWR For 2port Vector Network Analyzer 1.01 to 10.00
Cable Loss For 2port Vector Network Analyzer 0.00 to 30.00 dB
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB Yes
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible Yes
Phase Range For 2port Vector Network Analyzer -180 to +180 degree
Phase Resolution For 2port Vector Network Analyzer 0.01 deg
RF Output Port For 2port Vector Network Analyzer Type N, female, 50Ohm
Dynamic Range For 2port Vector Network Analyzer 60 dB
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. 1 MHz to 8 GHz: +5 dBm, typical (High); –20 dBm, typical (Low) >8 GHz to 20 GHz: –3 dBm, typical (High); –20 dBm, typical (Low)
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible Yes
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available NA
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared Yes, Less than 180 degree of phase change within the aperture
Operating Temperature 5 to 40 degree C & 80 RH 40 degree C
Power Requirement 230 +- 10 VAC, 50Hz
Warranty 3 years
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works yes
One Set Of Operation And Maintenance Manual Shall Be Supplied yes
Standard Accessories Shall Be Supplied yes
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications yes
Test Report No Yes
Test Report Date Yes
Name Of Lab Anritsu Company
Address Of The Lab 490, Jarvis Drive, Morgan Hill, CA 95037 USA

Price Dekho Price Dekho Price List in india