True RMS Clamp meter - FLIRs CM85 industrial-grade power clamp meters are engineered with advanced power analysis and variable frequency driveVFD filtering functions required by electrical troubleshooters. The CM85 meters offer additional features including Bluetooth technology to connect compatible mobile devices for remote viewing and sharing,and METERLiNK technology, to wirelessly embed electrical readings intoradiometric infrared images on compatible FLIR thermal cameras..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 45 mm |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | 0 to 50 Degree C |
Operating Humidity (RH) | 30 to 40 degrees @75% % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
Standard Accessories Supplied With The Equipment | Protective Case,AC Current Line Splitter,CAT IV Insulated Alligator Clips,.CAT IV Silicone Test Leads |
Dimensions (H X W X L) | 49 x 100x 262 mm x mm x |
Weight | 590 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | CE150824C11 |
Test Report Date | 20.04.2016 |
Name Of The Lab | COC - ADT, CE, Taiwan - ROC |