"Product Catgeory","signal generator" "Product Name","3 GHz RF Signal Generator - Keysight N9310A" "Specification Title","Specification Value" Type,"RF Signal Generator" "Frequency Range","9 KHz to 3 GHz" "Frequency Resolution","0,1" "Ageing Rate for reference frequency (As declared by OEM)","Less than 2" "Temperature stability for reference frequency","Less than 2" "SSB Phase Noise at 1GHz,on 20KHz offset (dBc/Hz)","less than -95" "Harmonics at 3 GHz level at 0 dBm","less than -30" "Non Harmonics (>10 KHz carrier offset)","less than -50" "Non Harmonics (>50 KHz carrier offset)",NA "Reverse Power Protection","DC voltage: 30 V RF power: +36 dBm" "Minimum Output Level",-120 "Maximum Output Level",+13 "Output Level Resolution","0,1" "Total Accuracy forall specified Output Level at 25 Degree C in continuous wave mode","< 1 dB" "VSWR on all operating frequencies",1.8 "Memory (Minimum Storage Settings)",16 "Amplitude Modulation (AM) Operating Modes","Internal & External" "Minimum Amplitude Modulation Frequency (3 dB), f > 100 KHz",20Hz "Maximum Amplitude Modulation Frequency (3 dB), f > 100 KHz",20KHz "Modulation Depth","0 to 100%" "Resolution of AM",0.1% "AM Distortion at 1 KHz","< 2" "Frequency Modulation (FM) Operating Modes","Internal & External" "Minimum Frequency Modulation Frequency (-3 dB) Standard",20Hz "Maximum Frequency Modulation Frequency (-3 dB) Standard",80KHz "Minimum Frequency Deviation","0.02 KHz" "Maximum Frequency Deviation",100KHz "Resolution of FM","< 1, Minimum 1 Hz" "Setting Error (at AF=1 KHz and 50% max. Deviation) for FM","< (5 of FM deviation +300 Hz)" "Phase Modulation",Available "If Available, Phase Modulation Operatinf Mode","Internal & External" "Minimum Phase Deviation","0 Rad" "Maximum Phase Deviation","10 Rad" "Resolution of Phase Modulation",1 "Setting Error (at AF=1 KHz) for Phase Modulation","< (5 of deviation +0.2 rad)" "Internal Modulation Generator For AM/FM/PM","20Hz to 80KHz with resolution of 0.1 Hz" "Pulse Modulation",Available "If Available, Pulse Modulation Operating Modes","Internal & External" "Rise and Fall Time","< 3 s" "On/Off Ratio","≥ 40 dB" "Minimum Pulse Width","100 μs to 1 s" "Input Level",TTL "RF Digital Sweep Range and Width","9 kHz to 3.0 GHz" "RF Digital Sweep Time Range","10 ms to 1 s" "RF Analog sweep",Not-Available "If Available, RF Analog Sweep Range and Width",NA "RF Analog Sweep Time Range",NA "Pulse Generator",Not-Available "If Available, Pulse Generator Operating Mode",NA "Pulse Width",NA "Pulse Delay",NA "Pulse Period",NA "Vector Modulation",Not-Available "Internal Base Band Generator Bandwidth",NA "Arbitory waveform memory",NA Modulation,NA "Error Vector Magnitude (EVM)",0 "Phase Modulator",Not-Available "If available, Range of Modulating Signal (Wide Mode)",NA "If available, Range of Modulating Signal (Narrow Mode)",NA "Interface Available","USB Interface" "Standard Acessories (To be supplied)","Quick Start Guide, USB cable Country-specific power cord Documentation set (CD-ROM) 3-year return-to-Keysight warranty" "Power Requirements","230 V +/-10% AC, 50 Hz +/- 3%" "Operating Temperature Range","5 to 45 Degree C" "Operating Humidity (RH)","Yes Available" ""Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification including environmental tests as under : 1. Dry Heat Test : 45 deg C for 16 hours as per IS:9000/Pt.3/sec.5/1977 (reaffirmed in 2007) 2. Cold test : 0 deg C for 4 hours as per IS:9000/Pt.2/sec.4/1977 (reaffirmed in 2007) 3. Damp Heat Test: 95% RH at 45 deg C, two cycles of 24 hours each separated by a gap of 4 hours as per IS:9000/Pt.5/sec. 1/1991 (reaffirmed in 2007) All the functional paramteres are to be verified before and after recovery period of 1 hours of above environmental test sequence as above. There shall be no deterioration in functional parameters.",Yes "Test Report No.",NTH(SR)/EL(C)/2013/024M "Test Report Date",04/02/2013 "Name of the Lab","NTH Taramani, Chennai" Warranty,3