"Product Catgeory","breath alcohol analyzers" "Product Name","Portable Digital LCD Display Alcohol Tester" "Specification Title","Specification Value" "Sensor Technology","Electrochemical - Fuel cell (alcohol specific)" "Sampling Method","Deep Lung Exhalation sample should be drawn into the sensor." "Sampling Error Detection and alarm on wrong sampling in the Unit",Yes "Units of measure (i.e. 0-400 mg/100 ml BAC or better(Blood alcohol concentration) (Details of other units of measurement possible by the instrument shall be mentioned)",0-550 "Measuring Range (0-400 mg / 100 ml BAC or better)",Yes "Accuracy (± 5 % or better)","+/-10% at 0.05%" "Drift of the breath analyzer should be less than 2 mg/100 ml. BAC in 6 months period and does- not require re-calibration before six months.",Yes "Mouth piece used for sampling shall be able to filter out sputum and oral contaminants such as pan masala etc. so that it should not reach fuel cell and damage it, by virtue of its design. Mouth piece shall be easy to replaceable with a new one.",Yes "Response Time",30 "Response Time (At 0 level of Alcohol)",5 "Recovery Time (At 0.50 mg/ltr.)",100 "Warm up Time (after putting on)",15 "Barometric Pressure Range (Should be b/w 600 to 1300 hpa and OEM declaration shall be furnished)",Yes "Operating Temperature","- 5 °C to +50 °C" "Display Type (TFT/LCD or better)",LCD "Display Size",2.4 "Availability of audible beeper for over range, low battery etc.",Yes "Alpha numeric Record Entry Keyboard",Yes "Min. Record Fields","Full information as per the user requirements like Driver Name, Vehicle No, Inspector Name, test result with time, Location, Instrument no., calibration date, Test No etc. and Location, Longitude & Latitude for GPS (If Applicable)(Note : the fields shall be customized as per the user's requirements)" "Record Memory (Min.)",4000 "Record Data Downloadable to PC",Yes "Data Interface","USB/ Wi-Fi 802.11/ Bluetooth (It shall not be possible to feed any programme or data to the breath analyzer from an outside source through any input port of the device)" "Shelf Life of Fuel Cell",3 Calibration,"Every 6 months (recommended) and Device shall have self calibration facility." "Battery (of Analyzer)","Suitable rechargeable (through mains 230 + or - 10% Volts, 50Hz) battery along with Battery charger." "Battery Voltage, AH Capacity and Battery Chemistry (Analyzer)",1.5*2V "Breath Analyzer battery back up / Capacity should support continuously 24 hours and it should support to generate 500 tests (minimum) results once it is fully charged and device should have low battery indicator.",Yes Printer,"Dot Matrix Printer with Wireless/bluetooth connectivity." "Printer offered /Supplied shall have BIS Registration under "Compulsory registration scheme of IT products" of Department of Electronics and Information Technology.",Yes "Print Method","Impact Type" "Print Resolution",200 "Battery Capacity (Printer)","Printer battery shall be rechargeable battery (through mains 230 + or - 10% Volts, 50Hz) along with Battery charger and capable of priting at least 60 test reports per day with at least 12 hours of standby operation." "Battery Voltage, AH Capacity and Battery Chemistry (Printer)",1.5*2V GPS,No Camera,No "Standard Accessories","Equipment shall be supplied with all essential accessories like printer with wireless or blue tooth connectivity, battery for the equipment, battery for the printer, battery chargers for equipment and printer, necessary software, mouth piece, cables, connectors, carrying case etc." "Breath analyzer is used as an evidential instrument for Traffic Law Enforcement. The instrument shall be hand held, portable and easy to operate.",Yes "Spare Battery shall be available with the supplier of Breath Analyzer. And, Instrument must also work through automobile 12 V dc power.",Yes "The equipment offered shall meet the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications as applicable on date. The product offered meets all the statutory requirements.",Yes "The Device should have immunity to RF interface. A certificate or declaration for EMI standard to which their product complies. The device shall meet RFI requirement as per EN:5008-1/1992(emission) and EN 50082-1:1997(immunity) or equivalent requirements.",Yes "RoHS Compliant (OEM self declaration shall be furnished )",Yes "Availability of Type tests reports from a Central Govt. lab OR International Laboratory Accreditaion Cooperation (ILAC)or their worldwide affiliated/ recognised labs OR NABL approved lab covering all declared parameters.",Yes "Name of the Lab",NA "Address of the Lab",NA "Test Report No. and date",NA "The equipment shall be subjected to the following environmental tests sequences: a. Dry Heat Test: For 16 hrs at a temp. Of 50 degree C as per IS: 9000/part-3/section-5/1977 (reaffirmed 2007). b. Cold Test: For 4 hrs at a temp. of (-) 5 degree C as per IS: 9000/part-2/section-4/1977(reaffirmed 2007). c. Damp Heat Test: For 2 cycles of 24 hrs (16 + 8h) each at a temp. 40 degree C & 95% RH as per IS: 9000/part-5/section-1/1981 (reaffirmed 2007), After each environmental test and recovery period of 2 hours the accuracy of equipment shall be checked and the results shall be with in limits. The accuracy of equipment shall be checked before conditioning, during last half an hour of conditioning (if checking of the accuracy is not possible with the equipment inside the environmental chamber, the equipment may be taken out for a few seconds to feed it with calibrated sample to check the accuracy) and after conditioning. All the test results shall be satisfactory.",Yes "Acceptance Tests: a. Verification of all the features. b. Accuracy at (-)5 deg celsius and 50 deg celsius (Firm shall have necessary environmental chamber for the test. The equipment shall be kept inside the chamber for two hours at (-)5 deg celsius and accuracy shall be checked with in a few seconds of taking out the equipment from the chamber. To check the accuracy at 50 deg celsius the equipment shall be kept inside the chamber for two hours at 50 deg celsius and accuracy shall be checked with in a few seconds of taking out the equipment from the chamber).",Yes "At the time of supply, vendor shall ensure that all the breath analyzers supplied are calibrated. 5% of the the breath analyzers supplied will be checked for calibration, from a Govt lab/NABL approved lab. /consignee's lab at the time of initial supply, by the consignee. Thereafter the breath analyzers shall be calibrated once in every six months and 5% of the the breath analyzers so calibrated will be checked for calibration from a Govt lab/NABL approved lab.or consignee's lab, by the consignee.",Yes "Indigenous manufacturer, shall have the facility to manufacture the product from the component level, facility to solder the components to the PCB, facility for conformal coating for humidity sealing.",Yes "Sampling modes","Active and Passive"