"Product Catgeory","signal generator" "Product Name","40 GHz Signal Generator" "Specification Title","Specification Value" Type,"RF Signal Generator" "Frequency Range","10 MHz to 40 GHz" "Frequency Resolution","0,1" "Ageing Rate for reference frequency (As declared by OEM)","Less than 2" "Temperature stability for reference frequency","Less than 2" "SSB Phase Noise at 1GHz,on 20KHz offset (dBc/Hz)","less than -105" "Harmonics at 3 GHz level at 0 dBm","less than -30" "Non Harmonics (>10 KHz carrier offset)","less than -60" "Non Harmonics (>50 KHz carrier offset)","less than -55" "Reverse Power Protection","Less than 1 Watt" "Minimum Output Level",-120 "Maximum Output Level",+5 "Output Level Resolution","0,1" "Total Accuracy forall specified Output Level at 25 Degree C in continuous wave mode","≤±1 dB dB" "VSWR on all operating frequencies",2 "Memory (Minimum Storage Settings)",10 "Amplitude Modulation (AM) Operating Modes","Internal & External" "Minimum Amplitude Modulation Frequency (3 dB), f > 100 KHz","DC to 50 kHz minimum Hz" "Maximum Amplitude Modulation Frequency (3 dB), f > 100 KHz","DC to 100 kHz typical KHz" "Modulation Depth","0 % to 90 % (nominal) %" "Resolution of AM",10% "AM Distortion at 1 KHz","less than < 5 typical" "Frequency Modulation (FM) Operating Modes","Internal & External" "Minimum Frequency Modulation Frequency (-3 dB) Standard","Unlocked: DC to 10 MHz Locked:1 kHz to 10 MHz" "Maximum Frequency Modulation Frequency (-3 dB) Standard","Unlocked: DC to 10 MHz Locked:1 kHz to 10 MHz" "Minimum Frequency Deviation","DC to 8 MHz" "Maximum Frequency Deviation","DC to 8 MHz KHz" "Resolution of FM",10% "Setting Error (at AF=1 KHz and 50% max. Deviation) for FM","10 % (5 % typical)" "Phase Modulation",Available "If Available, Phase Modulation Operatinf Mode","Internal & External" "Minimum Phase Deviation","DC to 8 MHz Radians" "Maximum Phase Deviation","10% Radians" "Resolution of Phase Modulation",1 "Setting Error (at AF=1 KHz) for Phase Modulation",10% "Internal Modulation Generator For AM/FM/PM","0.1 Hz to 10 MHz sinusoidal 0.1 Hz to 1 MHz square-wave, triangle, ramps 0.1 Hz" "Pulse Modulation",Not-Available "If Available, Pulse Modulation Operating Modes",NA "Rise and Fall Time",NA "On/Off Ratio",NA "Minimum Pulse Width",NA "Input Level",NA "RF Digital Sweep Range and Width","Width: 8MHz to full range" "RF Digital Sweep Time Range","1 ms to 99 s" "RF Analog sweep",Not-Available "If Available, RF Analog Sweep Range and Width",NA "RF Analog Sweep Time Range",NA "Pulse Generator",Available "If Available, Pulse Generator Operating Mode","Automatic, externally triggered, external gate mode, single pulse, double pulse, delayed pulse(externally triggered)" "Pulse Width","10 ns to 1.6 s" "Pulse Delay","100 ns to 1.6 s" "Pulse Period","100 ns to 1.6 s" "Vector Modulation",Not-Available "Internal Base Band Generator Bandwidth",NA "Arbitory waveform memory",NA Modulation,NA "Error Vector Magnitude (EVM)",0 "Phase Modulator",Available "If available, Range of Modulating Signal (Wide Mode)","DC to 1 MHz: ± [Lesser of 400 rad" "If available, Range of Modulating Signal (Narrow Mode)","DC to 8 MHz: ± [Lesser of 3 rad" "Interface Available","IEEE 488 & LAN" "Standard Acessories (To be supplied)",""Software for MG3690X Operation Manual Programming Manual SCPI Programming Manual IVI Drivers Technical Datasheet CAT-7 shielded, twisted-pair, Ethernet cable, 10 ft. Power Cord with plug-type"" "Power Requirements","230 V +/-10% AC, 50 Hz +/- 3%" "Operating Temperature Range","0 °C to +50 °C Degree C" "Operating Humidity (RH)","5 % to 95 % %" ""Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification including environmental tests as under : 1. Dry Heat Test : 45 deg C for 16 hours as per IS:9000/Pt.3/sec.5/1977 (reaffirmed in 2007) 2. Cold test : 0 deg C for 4 hours as per IS:9000/Pt.2/sec.4/1977 (reaffirmed in 2007) 3. Damp Heat Test: 95% RH at 45 deg C, two cycles of 24 hours each separated by a gap of 4 hours as per IS:9000/Pt.5/sec. 1/1991 (reaffirmed in 2007) All the functional paramteres are to be verified before and after recovery period of 1 hours of above environmental test sequence as above. There shall be no deterioration in functional parameters.",Yes "Test Report No.","A2LA Cert. No. 2160.01" "Test Report Date",06/01/2016 "Name of the Lab","Anritsu Company, 490, Jarvis Drive, Morgan Hill, CA 95037 USA" Warranty,3