"Product Catgeory","power quality analyzers" "Product Name","single phase power quality analyzer" "Specification Title","Specification Value" "Type of Power analyzer","Single phase" "Display type","LCD Backlit" "Display Mode","70 mm Diagonal" "Number of Current Channels",01 "Number of Voltage Channels",01 "Facility to Measure RMS Voltage",Available "Measurable voltage range",825 "Measurable voltage accuracy","V > 1 V: ± 1 % rdg ± 5 digits, V" "Measurable voltage resolution","1 mV in 4 V range, 10 mV in 40 V range, 100 mV in 400 V range, 1 V in 750 V range" "Facility to Measure RMS Current",Available "Measurable current range","0 to 2000 A dc or 1400 ac rms" "Measurable current accuracy","I > 10 A: ± 1.5 % rdg ± 5 digits,I" "Measurable current resolution","10 mA in 40 A range,100 mA in 400 A range,1 A in 2000 A range" "Facility to Measure Active, Reactive and Apparent Power",Available "Maximum power that can be measured","0 to 1650 kW dc or 1200 kW ac" "Power Accuracy","2.5 % rdg ± 5 digits, W1Ø" "Power resolution","1 VA in 4 kVA,10 VA in 40 kVA,100 VA in 400 kVA 1 kVA in 1200 kVA" "Facility to Measure Active, Reactive and Apparent Energy",Available "Facility to Measure sag(dips) and swell(surge)",Available "Facility to Measure Frequency",Available "Frequency range that can be measured","15 Hz to 1 kHz" "Facility to Measure Total Harmonic distortion",Available "Accuracy in measurement of Total Harmonics distortion","± 3 % rdg ± 5 digits, ± 5 % rdg ± 5 digits" "Resolution in measurement of Total Harmonics distortion",0.1% "Facility to Measure Inter harmonics",Available "Order(n) to which Facility to Measure Harmonics available",30 "Facility to Measure Power Factor",Available "Accuracy in measurement of Power Factor","± 3°" "Facility to Measure Distortion Factor",Available "Accuracy in measurement of Distortion Factor","± 3 % rdg ± 5 digits,± 5 % ± 2 digits,± 10 % ± 2 digits" "Facility to Measure Ripple Factor",Available "Accuracy in measurement of Ripple Factor","2 % ≤ RPL" "Facility to Measure voltage and current unbalance",NA "Facility to Measure inrush current",Available "Facility to Measure flicker",Available "Facility to Measure crest factor",Available "Measurable crest factor range","1.1 ≤ CF" "Measurable crest factor accuracy","1.1 ≤ CF" "Measurable crest factor resolution",0.01% "Screen memory",Available "Data transfer software provided for analysis on PC",Yes "Internal Memory",Available "Type of Battery used","Battery type 1.5 V Alkaline" "Battery backup","> 10 hours (backlight on full), > 12 hours (backlight reduced)" "Power Supply(volts in AC)",230 "Weight of the analyser",820 Dimensions(LXWXH),"30.0 X 9.8 X 5.2" "Provision for external SD Card",No "Operating Temperature range","0 °C to 50 °C" "Operating Humidity","80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F)" "All connecting Cables and accessories to be supplied along with the Analyzer",Yes "Details of All connecting Cables and accessories to be supplied along with the Analyzer","345 Power Quality Clamp Meter, Soft carrying case, Power Log software, Test leads, Alligator clips, Test probes, USB cable, International ac adapter / battery eliminator, Printed English language user manual, Multi-language manual CD" "Compliance to IEC 61000-4-30",Yes "Category of safety rating","Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2" "Dry Heat test as per IS :9000(Part 3/Section 5)",Yes "Damp heat(cyclic test): two cycles of 24 hours each as per IS: 9000(Part 5/section 1)",Yes "Cold test at -20 degree C for four hours as per IS: 9000(Part2 /section 4)",Yes "Availability of Type Test Report from Central Govt. /NABL/ILAC Accredited lab. To prove confirmity to the specification.",Yes "Type Test report No.",STANDARD "TTC report date",STANDARD "Name of Lab",STANDARD "Address of Lab",STANDARD Interface,USB