"Product Catgeory","digital earth resistance meter" "Product Name","fluke 1623 -2 kit" "Specification Title","Specification Value" "Display type","3½ digit LCD display" "Measurable Earth resistance range","Auto ranging" "2-pole method for resistance measurement",YES "3-pole method for resistance measurement",YES "4-pole method for resistance measurement",YES "Number of the stakes","04 NOS" "Material of the stakes","GI Steel" "Length of the Stakes","46 Cm" "Diameter of the Stakes","0.8 Cm" "Number of the Test Leads","1 set of Testleads and Reel Cables of.. (1) 50 m cable reel of red wire.. (1) 25 m cable reel of blue wire.. (1) 25 m cable reel of green wire Nos." "Length of the Test Leads","Test leads- 1.5 M and Reel Cables 25 m - 2 nos and 50 m- 1 no cm" "No. of Test Leads with Clamps","02 Nos." "Length of Test Leads with Clamps","150 cm" "Measuring Range1 for earth resistance","0.02 Ohm to 19.99 K Ohms" "Measuring Range2 for earth resistance","0.02 Ohm to 19.99 K Ohms" "Measuring Range3 for earth resistance","0.02 Ohm to 19.99 K Ohms" "Measuring Range4 for earth resistance","0.02 Ohm to 19.99 K Ohms" "Measuring Range5 for earth resistance","0.02 Ohm to 19.99 K Ohms" "Measuring Range6 for earth resistance","NA Ohms" "Measuring Range7 for earth resistance","NA Ohms" "Measurable Earth resistance resolution for Range1","0.001 to 10 Ohms" "Measurable Earth resistance resolution for Range2","0.001 to 10 Ohms" "Measurable Earth resistance resolution for Range3","0.001 to 10 Ohms" "Measurable Earth resistance resolution for Range4","0.001 to 10 Ohms" "Measurable Earth resistance resolution for Range5","0.001 to 10 Ohms" "Measurable Earth resistance resolution for Range6","NA Ohms" "Measurable Earth resistance resolution for Range7","NA Ohms" "Measurable Earth resistance accuracy for Range1","± (2 % rdg + 3 d) ±% reading ± digits ±% reading ± digits" "Measurable Earth resistance accuracy for Range2","± (2 % rdg + 3 d) ±% reading ± digits ±% reading ± digits" "Measurable Earth resistance accuracy for Range3","± (7 % rdg + 3 d) ±% reading ± digits ±% reading ± digits" "Measurable Earth resistance accuracy for Range4","± (7 % rdg + 3 d) ±% reading ± digits ±% reading ± digits" "Measurable Earth resistance accuracy for Range5","± (7 % rdg + 3 d) ±% reading ± digits ±% reading ± digits" "Measurable Earth resistance accuracy for Range6","NA ±% reading ± digits" "Measurable Earth resistance accuracy for Range7","NA ±% reading ± digits" "Stakeless test(Clamp On)",yes "Facility to Measure Earth Voltage","Not Available" "If Yes,Measurable Earth Voltage range","NA Volts" "If Yes,Measurable Earth Voltage accuracy","NA %" "Minimum Open Circuit Output voltage","48 Volts" "Low battery indication",Available "Over range indication",Available "If Yes,Measurable Earth Voltage resolution","NA Volts" "Internal Memory",1500 "Type of Battery used in the power supply",AA "Battery backup time",">3000 measurements, typical, RH + RE 6000 measurements, typical, RH + RE > 10 kOhm Hours" "Battery Charger provided with the Meter.",NA "Weight of the tester","1100 grams" Dimensions(LXWXH),"25X13.3X18.7 cmXcmXcm" "Provision for external SD Card",No Interface,"YES, USB" "Operating Temperature range","-10 °C to 50 °C degree celsius" "Operating Humidity range","5-95 %" "All connecting Cables and accessories to be supplied along with the tester.",Yes "Details of All connecting Cables and accessories to be supplied along with the tester.","GEO Earth Ground Tester User’s Manual Batteries Quick Reference Guide USB Cable 2 Clamps C1620 Professional Carrying Case 4 Earth Ground Stakes 3 Cable Reels" "Availability of Type Test Report from Central Govt. /NABL/ILAC Accredited lab. To prove confirmity to the specification including Environmental Test Sequence. 1. Dry Heat test as per IS :9000(Part 3/Section 5) 2.Damp heat(cyclic test): two cycles of 24 hours each as per IS: 9000(Part 5/section 1) 3.Cold test at -20 degree C for four hours as per IS: 9000(Part2 /section 4). After completion of environmental conditioning sequence as specified and recovery of 2 hours, the functional parameters of Earth resistance meter shall be checked.",Yes "Type Test report No.",CAL/2017 "TTC report date",30/11/17 "Name of Lab",TRANSCAL "Address of Lab","TRANSCAL LAB, MALLESHWARAM BANAGLORE"