"Product Catgeory","computer servers" "Product Name","dell poweredge r740 server" "Specification Title","Specification Value" "Processor Configuration","Intel Xeon Gold 6130 (2.10GHz/16-core/22MB/125W)" "Form Factor",Rack "Processor Make",Intel "Max. Number of sockets available on chipset",2 "Max. Number of sockets populated with processor",2 "No. of Processor",2 "Number of core per Processor",16 "Chipset compatible with CPU",c620 "Motherboard (OEMcompatible with CPU)",Yes "PCI Slots (Express Gen 3.0 min.)","Up to 8 x Gen3 slots, Up to 4 x16" "Max Nos of PCI Lanes",48 "Memory ( DDR4 RAM min.)",512 "DDR4 RAM upgradable upto (Minimum)",1536 "DIMM Slots (Minumum)",24 "Hard disk drive Capacity",2X600 "Hard disk drive RPM with SAS (hot plug or better )",15000 "RAID Controller Caches",0 "RAID Controller","PERC H330+ RAID Controller" "RAID Controller Ports",12 "Video Controller (support VGA or above resolution)",Yes Keyboard,standard Mouse,"Optical scroll" "Bays (min. 2 internal or more hot plug)","Up to 16 x 2.5” SAS/SATA/SSD, max 60TB Up to 8 x 3.5” SAS/SATA, max 80TB" "USB Ports (version 2.0/3.0)",5 "Certifications, Compliance & support by Windows, Red Hat or Novell.",Yes "DVD ROM (or better)","8x or better" "Networking: dual LAN (10/100/1000) network card with asset feature tracking & security management, remote wake up",Yes "FC HBA Dual port card",Available "FC HBA Dual port card Speed","Server configured with dual adapter of dual port 16 Gbps Fiber Channel to external storage." "Power Management","Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected" "Redundant Power Supply",Yes "Redundant Fan",Yes "Server scalability to be achived within the box & without adding nodes",NA "Avaialbiklity of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a. Dry heat test (For 16 hrs at a temp. Of 45 degree C in accordance with IS: 9000/part-3/section-5/1977). b. Cold test(For 4 hrs at a temp. of 0 degree C in accordance with IS: 9000/part-2/section-4/1977. c. Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temp. 40 degree C & 95% RH in accordance with IS: 9000/part-5/section-1/1981) Note:- The server shall be checked for all the parameters before conditioning. After completion of the above environmental tests sequence, with a recovery period of 1 to 2 hrs, the server shall be functional.",No "Availability of the type test report from Central Govt./ NABL/ ILAC acredited lab. covering verification of all features & functional parameters & environmental tests sequence.",No "Test Report No. & date",NA "Name & address of Lab",NA "BIS Registration no. under CRS of Deity","N/A. Additionl Features Failure Alerting Mechanism - The server is able to alert impending failures on server component to administrator in order Management Functionality - support for integrated management with remote presence, Server should be supplied with OEM Server Virtualization Support - Server supports latest version of virtualization software such as VMware, RHEV, Microsoft Hype Gartner - OEM in Leaders/Challengers in Gartners latest magic quadrant for servers" "Declare SPEC int_rate_base 2006 & specfp_rate_2006 for 1,2,4,8 prcessor as applicable.","N/A. Redundant Fan - Server configured hot-swap redundant cooling fans with support N+1 redundancy. Fans are completely redundant so that failure of a fan should not impact the cooling inside the server chassis and will provide availability for business-critical applications" "Declare max. power consumption of the system",750 "Availability of documentary evidence in support of model quoted in commersial production & due evaluation completed",Yes "Details of benchmark indices with software & diagnostic software used to test server.","ABOVE BENCHMARK SCORE 1135 USNG SPEC CPU2006 WITH THE QUOTED PROCESSOR AND 512 GB RAM" "Server main supply","230V, ±10%,50 Hz" "CE or UL certified or Ertl/Etdc certified for safety (IEC-60950-1)",Yes "RoHS Compliance",Yes Warranty,5