"Product Catgeory","computer servers" "Product Name","dell poweredge 730 rack server 2u" "Specification Title","Specification Value" "Processor Configuration","E5-2609 v4, 8 core, 1.70 GHz with 20 MB smart cache memory, 85 watt" "Form Factor",Rack "Processor Make",Intel "Max. Number of sockets available on chipset",2 "Max. Number of sockets populated with processor",2 "No. of Processor",1 "Number of core per Processor",8 "Chipset compatible with CPU","c600 Series" "Motherboard (OEMcompatible with CPU)",Yes "PCI Slots (Express Gen 3.0 min.)",3 "Max Nos of PCI Lanes",32 "Memory ( DDR4 RAM min.)","2 x 16 GB" "DDR4 RAM upgradable upto (Minimum)","768 or more" "DIMM Slots (Minumum)","16 or More" "Hard disk drive Capacity","6 x 600 GB" "Hard disk drive RPM with SAS (hot plug or better )","15000 SAS RPM" "RAID Controller Caches",1000 "RAID Controller","Dell 1 GB (SAS RAID Controller/ RAID 5/ RAID 0/1)" "RAID Controller Ports",12G "Video Controller (support VGA or above resolution)",Yes Keyboard,standard Mouse,"Optical scroll" "Bays (min. 2 internal or more hot plug)",8 "USB Ports (version 2.0/3.0)",4 "Certifications, Compliance & support by Windows, Red Hat or Novell.",Yes "DVD ROM (or better)","8x or better" "Networking: dual LAN (10/100/1000) network card with asset feature tracking & security management, remote wake up",Yes "FC HBA Dual port card",Not-Available "FC HBA Dual port card Speed","Not Available" "Power Management","Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected" "Redundant Power Supply",Yes "Redundant Fan",Yes "Server scalability to be achived within the box & without adding nodes",Yes "Avaialbiklity of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a. Dry heat test (For 16 hrs at a temp. Of 45 degree C in accordance with IS: 9000/part-3/section-5/1977). b. Cold test(For 4 hrs at a temp. of 0 degree C in accordance with IS: 9000/part-2/section-4/1977. c. Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temp. 40 degree C & 95% RH in accordance with IS: 9000/part-5/section-1/1981) Note:- The server shall be checked for all the parameters before conditioning. After completion of the above environmental tests sequence, with a recovery period of 1 to 2 hrs, the server shall be functional.",Yes "Availability of the type test report from Central Govt./ NABL/ ILAC acredited lab. covering verification of all features & functional parameters & environmental tests sequence.",No "Test Report No. & date","NA. NA. IMPORTANT NOTE: Microsoft Genuine Windows Server 2016 -64 bit with 68 CAL licenses and 1Gb Ethernet 4 -port Adapter IS INCLUDED IN SERVER AS REQUIRED" "Name & address of Lab","NA NA. IMPORTANT NOTE: Microsoft Genuine Windows Server 2016 -64 bit with 68 CAL licenses and 1Gb Ethernet 4 -port Adapter IS INCLUDED IN SERVER AS REQUIRED" "BIS Registration no. under CRS of Deity",NA "Declare SPEC int_rate_base 2006 & specfp_rate_2006 for 1,2,4,8 prcessor as applicable.","Will provide....IMPORTANT NOTE: Microsoft Genuine Windows Server 2016 -64 bit with 68 CAL licenses and 1Gb Ethernet 4 -port Adapter IS INCLUDED IN SERVER AS REQUIRED" "Declare max. power consumption of the system","900W ....................NA. IMPORTANT NOTE: Microsoft Genuine Windows Server 2016 -64 bit with 68 CAL licenses and 1Gb Ethernet 4 -port Adapter IS INCLUDED IN SERVER AS REQUIRED" "Availability of documentary evidence in support of model quoted in commersial production & due evaluation completed",Yes "Details of benchmark indices with software & diagnostic software used to test server.","Benchmark SPEC CPU 2006" "Server main supply","230V, ±10%,50 Hz" "CE or UL certified or Ertl/Etdc certified for safety (IEC-60950-1)",Yes "RoHS Compliance",Yes Warranty,3