× All the transactions performed on 2.0 is available here. To access Market click "Home".

megger 500 volt (MTC)(Megger 500)

` 7,780.00

  • MRP: `9150.00

Megger 500 Volt.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range -10 to +55 C 90 RH at 40 C max Degree C Degree C
Operating Humidity (RH) 90 RH at 40 C max %
Power Requirements Battery Operated
Type Of Battery 6 x 1.5 V cells type IEC LR6 AA, MN1500, HP7, AM3 R6HP Alkaline
PC Interface Available
Standard Accessories Supplied With The Equipment Red/Black Silicone test leads with Probes + Clips SP5 remote switch probe Owners information CD Batteries 6 x AA Alkaline Hard carry case
Dimensions (H X W X L) 228 mm x 108 mm x 63 mm 9.00 in x 4.25 in x 2.32 in mm x mm x mm x mm x
Weight 600g gms gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 1546
Test Report Date 26/06/2017
Name Of The Lab QMS
Warranty 1

Price Dekho Price Dekho Price List in india