× All the transactions performed on 2.0 is available here. To access Market click "Home".

iron removal plant for 8000 ltr per hour (ocean water)(ow-power-iron-8)

` 1,426,800.00

  • MRP: `1598016.00

Iron removal plant with power operated valve for 8000 ltr per hour.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Prefilter Provided with Flushing Valve in the Iron Removal Unit - NO
  • Iron Removal Unit Suitable for Water Supply Equipment - Tubewell
  • Discharge Capacity of the Iron Removal Equipment - 8000 LPH
  • Diameter of Vessel of Iron Removal Equipment - 762 +/- 100 mm
  • Minimum Thickness of Vessel of Iron Removal Equipment - NOT APPLICABLE mm
Other Specifications Download Specification
Iron Removal Unit Without
Prefilter Provided With Flushing Valve In The Iron Removal Unit NO
Iron Removal Unit Suitable For Water Supply Equipment Tubewell
Discharge Capacity Of The Iron Removal Equipment 8000 LPH
Material Of Body Of Iron Removal Equipment FRP
Diameter Of Vessel Of Iron Removal Equipment 762 +/- 100 mm
Height Of Vessel Of Iron Removal Equipment 1828 +/- 100 mm
Number Of Iron Removal Vessel 1 Nos
Minimum Thickness Of Vessel Of Iron Removal Equipment NOT APPLICABLE mm
Material Of Strainer Plate Of Iron Removal Equipment NOT APPLICABLE
Diameter Of Strainer Plate Of Iron Removal Equipment NOT APPLICABLE mm
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment NOT APPLICABLE mm
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment NOT APPLICABLE Nos
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment NOT APPLICABLE Nos
Material Of Strainer In Strainer Plate Of Iron Removal Equipment NOT APPLICABLE
Quantity Of Iron Removal Media In Iron Removal Vessel 275 +/- 10 Kg
Quantity Of Filter Media In Iron Removal Media 85 +/- 10 Kg
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel 25% +/- 5%
Back Wash Valve In Iron Removal Vessel Automatic Operated Valve System connected to Electric Supply and operated by a timer
The Accumulated Ferric Is Removed From The Media While Back Washing YES
Maximum Iron Content Of Inlet Water 10 ppm
Maximum Iron Content Of Outlet Water 0.3 ppm
Process By Which Iron Is Removed From Water By Iron Removal Media Iron removal media work on oxidation process
Life Of Iron Removal Media 3 Years
Cost Of Refilling Of Iron Removal Media 123750.00 Rupees
Life Of Iron Removal Unit 8 Years
Protective Coating Of Iron Removal Vessel UV
Inlet Pipe Size Of Iron Removal Unit 40 mm
Space Required For Installation Of Iron Removal Unit 1.5 Square Metres
Number Of Valves In Iron Removal Unit 1 Nos
Materal Of Valve Of Iron Removal Unit ABS
Diameter Of The Valve In Iron Removal Unit 40 mm
Pressure Gauge In Iron Removal Unit YES
Pressure Release Valve In Iron Removal Unit YES
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit 6 kg/cm2 Kg/square cm
Weight Of Iron Removal Unit 290 Kg
Warranty Period Of Iron Removal Unit 3 Years
Arsenic Removal Unit Without
Discharge Capacity Of The Arsenic Removal Unit NOT APPLICABLE LPH
Arsenic Removal Unit Suitable For Water Supply Equipment Tubewell
Material Of Arsenic Removal Vessel NOT APPLICABLE
Diameter Of Arsenic Removal Vessel NOT APPLICABLE mm
Height Of Arsenic Removal Vessel NOT APPLICABLE mm
Minimum Thickness Of Arsenic Removal Vessel NOT APPLICABLE mm
Number Of Arsenic Removal Vessel NOT APPLICABLE Nos
Material Of Strainer Plate Of Arsenic Removal Vessel NOT APPLICABLE
Diameter Of Strainer Plate Of Arsenic Removal Vessel NOT APPLICABLE mm
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel NOT APPLICABLE mm
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate NOT APPLICABLE Nos
Material Of Strainer In Arsenic Removal Strainer Plate NOT APPLICABLE
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel NOT APPLICABLE Kg
Media Used For Removal Of Arsenic From Water NOT APPLICABLE
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel NOT APPLICABLE
Maximum Arsenic Content Of Inlet Water NOT APPLICABLE ppm
Maximum Arsenic Content Of Outlet Water NA ppm
Life Of Arsenic Removal Media NOT APPLICABLE Years
Cost Of Refilling Of Arsenic Removal Media NOT APPLICABLE Rupees
Life Of Arsenic Removal Unit NOT APPLICABLE Years
Protective Coating Of Arsenic Removal Vessel NOT APPLICABLE
Inlet Pipe Size Of Arsenic Removal Unit NOT APPLICABLE mm
Space Required For Installation Of Arsenic Removal Unit NOT APPLICABLE Square Metres
Number Of Valves In Arsenic Removal Unit NOT APPLICABLE Nos
Materal Of Valve In Arsenic Removal Unit NOT APPLICABLE
Diameter Of The Valve Of Arsenic Removal Unit NOT APPLICABLE mm
Pressure Gauge In Arsenic Removal Unit NO
Pressure Release Valve In Arsenic Removal Unit NO
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit NOT APPLICABLE Kg/square cm
Weight Of Arsenic Removal Unit NOT APPLICABLE Kg
Warranty Period Of Arsenic Removal Unit NOT APPLICABLE Years
Iron Removal Media Conform To International Standard National Science Foundation, USA
Arsenic Removal Media Conform To International Standard National Science Foundation, USA
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate YES
Field Testing Kit For Testing Iron & Arsenic Is Provided YES

Price Dekho Price Dekho Price List in india