Blotting Unit includes 4Gel Vertical electrophoresis unit along with Mini Gel transfer unit in addition to High Current Power supply. 4-gel vertical electrophoresis system, 1.0 mm gel thickness, includes casting stand, 2 casting frames,10-well combs, glass plates 5 short plates and 5 spacer plates Run 1 to 4 gels in quick time. 5- 250V, 0.01-3.0 A, 1-300 W,Constant Voltage, Constant current or constant power,Timer 1min- 99 hr, 59 min, No. of Output Jacks 4sets in parallel, Programmable 1 method up to 3 stepsPause/Resume Function Yes, Safety Features No-load detection, sudden load change, EN61010, CE safety compliance, Mini trans blot Blotting Area 7.5x10cm, 2 cassettes, 4cm electrode distance, 450ml buffer requirement. Certificate should be provided by department that the product will be used for research purpose only along with DSIR Regn..
Other Specifications Download Specification | |
---|---|
Types Of System | Horizontal Gel Electrophoresis system |
Applications | To separate charged molecules like DNA/RNA and proteins according to the size |
Series Of Electrophoresis | Large |
No. Of Maximum Samples Which Can Run | 60 Nos |
Body Material Of Electrophoresis Unit | PC |
Size Of Unit (WxLxH) | 120160180 mm |
Gel Tray Requirements | The tray should be UV proof and should have integrated fluorescent ruler which should get illuminated on exposure to UV lights for easy and safe calculation of the band movement |
Material Of Gel Tray | PC |
Width Of The Gel Tray | NA cm |
Length Of The Gel Tray | 0 cm |
Thickness Of Combs And Colour Code | 1mm-white,1.5mm- Red,2mm-Blue |
All Combs Of Adjustable Height | Yes |
No. Of Wellcombs | 5 Nos |
Width Of Well,cm | 5.08 cm |
Length Of Well,cm | 1 cm |
Volume Of Gel,ml | 44 ml |
Type Of Electrode | Standard |
The Base Buffer Volume,ml | 1000 ml |
Details Of Other Components Included | mini trans blot |
Required Dye Chemicals | Standard |
Specified Voltage For Dye Migration | 200 V |
Dye Migration Rate | 16 cm/hr |
Maxi.output Voltage Of Power Supply Unit | 250 V |
Output Current | 3000 mA |
Ouput Wattage,W | 300 W |
Constant Voltage | Yes |
Constant Current | Yes |
Display | LCD display |
Control | Microprocessor controlled |
No. Of Electrode Terminal Ports | 4 Nos |
Alarm For Time Completion | No |
Timer Range Up To | 999 minutes |
Autostart After Power Breakdown | Yes |
Operating Voltage | 230 V |
Operating Temperature Range | 40 deg.C |
Power Unit Dimension (LxWxH) | 25028580 mm |
Weight Of Power Unit | 2 kg |
Warranty Period Of The System | 1 years |
Details Of Consumables To Be Supplied | Standard |
Installation,commissioning And Training Part Of The Supply | Yes |