× All the transactions performed on 2.0 is available here. To access Market click "Home".

signal generator 25 mhz synthesized (crescent)(sg25mhz)

` 119,500.00

  • MRP: `140520.00

Signal Generator Synthesized with sweep and burst function / usb interface/ Frequency range of Micro Hz to 25 Mhz with 1 Micro frequency resolution builtin 120 MSAs 10 bit resolution and arbitrary waveform editing function with 4k point memory / dual channel model support with coupling tracking and phase function/ square waveform can adjust the dutycycle from 1 to 99 / support various waveform arbitrary modes/ built in am/pm/fm/fsk and sum modulation /.

  • Availability: 50 In Stock
  • Min. Qty. Per Consignee: 1
  • Frequency Range - 9 KHz to 1 GHz
  • Frequency Resolution - 0,1 Hz
  • Ageing Rate for reference frequency (As declared by OEM) - Less than 1 PPM/Year
  • SSB Phase Noise at 1GHz,on 20KHz offset (dBc/Hz) - less than -95 dBc
  • Non Harmonics (>50 KHz carrier offset) - less than -55 dBc
Other Specifications Download Specification
Type RF Signal Generator
Frequency Range 9 KHz to 1 GHz
Frequency Resolution 0,1 Hz
Ageing Rate For Reference Frequency (As Declared By OEM) Less than 1 PPM/Year
Temperature Stability For Reference Frequency Less than 1 PPM
SSB Phase Noise At 1GHz,on 20KHz Offset (dBc/Hz) less than -95 dBc
Harmonics At 3 GHz Level At 0 DBm less than -30 dBc
Non Harmonics (>10 KHz Carrier Offset) less than -50 dBc
Non Harmonics (>50 KHz Carrier Offset) less than -55 dBc
Reverse Power Protection 5 Watt
Minimum Output Level -105 dBm
Maximum Output Level +5 dBm
Output Level Resolution 0,1 dB
Total Accuracy Forall Specified Output Level At 25 Degree C In Continuous Wave Mode +- 0.1 dB
VSWR On All Operating Frequencies 1
Memory (Minimum Storage Settings) 11
Amplitude Modulation (AM) Operating Modes Internal & External
Minimum Amplitude Modulation Frequency (3 DB), F > 100 KHz 3 Hz
Maximum Amplitude Modulation Frequency (3 DB), F > 100 KHz 3 KHz
Modulation Depth 5 %
Resolution Of AM 5
AM Distortion At 1 KHz 1
Frequency Modulation (FM) Operating Modes Internal & External
Minimum Frequency Modulation Frequency (-3 DB) Standard 5
Maximum Frequency Modulation Frequency (-3 DB) Standard 5
Minimum Frequency Deviation 5
Maximum Frequency Deviation 5 KHz
Resolution Of FM 1
Setting Error (at AF=1 KHz And 50% Max. Deviation) For FM 5
Phase Modulation Not-Available
If Available, Phase Modulation Operatinf Mode Internal & External
Minimum Phase Deviation NA Radians
Maximum Phase Deviation NA Radians
Resolution Of Phase Modulation NA %
Setting Error (at AF=1 KHz) For Phase Modulation NA
Internal Modulation Generator For AM/FM/PM 0.1
Pulse Modulation Available
If Available, Pulse Modulation Operating Modes Internal & External
Rise And Fall Time 1 ns
On/Off Ratio 80 dB
Minimum Pulse Width 1 ns
Input Level TTL
RF Digital Sweep Range And Width 1
RF Digital Sweep Time Range 5
RF Analog Sweep Available
If Available, RF Analog Sweep Range And Width NA
RF Analog Sweep Time Range 30
Pulse Generator Available
If Available, Pulse Generator Operating Mode Automatic, externally triggered, external gate mode, single pulse, double pulse, delayed pulse(externally triggered)
Pulse Width 30
Pulse Delay 1
Pulse Period 1
Vector Modulation Available
Internal Base Band Generator Bandwidth NA MHz
Arbitory Waveform Memory NA Mega samples
Modulation NA
Error Vector Magnitude (EVM) 1 %
Phase Modulator Not-Available
If Available, Range Of Modulating Signal (Wide Mode) NA
If Available, Range Of Modulating Signal (Narrow Mode) NA
Interface Available USB
Standard Acessories (To Be Supplied) Patch Chords and manual
Power Requirements 230 V +/-10 AC, 50 Hz +/- 3
Operating Temperature Range 10 to 45 Degree C
Operating Humidity (RH) 85 %
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. Yes
Test Report No. 468
Test Report Date 23.02.2012
Name Of The Lab ETDC Indore MP
Warranty 3 Years

Price Dekho Price Dekho Price List in india