15Kva online UPS with 60 Minutes backup time without isolation The Ultron EH series is an online double-conversion 3p-1p UPSwhich provides reliable power protection for IT rooms, SMBs,telecommunications, banking, medical facilities and industry. Supportedwith DSP based technology, it offers rapid computation capabilities thatenhance system stability and provide precise voltage to load. TheUltron EH series offers many superior features including NX parallel redundancy and a built-in manual bypass switch to guarantee higher availability and reliability for protecting your critical loads..
Other Specifications Download Specification | |
---|---|
Rating In KVA | 15 KVA |
Technology | IGBT-PWM without inbuilt isolation transformer |
Input Power | Three phase 300 V - 450V sinewave,50Hz |
Output Power | single phase 230V 1 sinewave,50Hz |
Backup Time | 60 Minutes |
Minimum VAH | 32000 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | No (only for IGBT-PWM Technology) |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 2 % |
Overall Efficiency | 90 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | Without trolley but with Rack |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | IR/10213013 |
Type Test Certificate Date | 05-SEP-2013 |
Name Of Lab | TUV INDIA |
Address Of Lab | TUV NORD GRUPS, TUV IND (P) LTD NEW DELHI |
Supply & Commissioning | YES |
Warranty | 2 Years |