× All the transactions performed on 2.0 is available here. To access Market click "Home".

Oscilloscope-30mhz (HTC)(HTC- 5030)

` 35,000.00

  • MRP: `45000.00

oscilloscope-30 mhz, dual trace.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Non -Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Analog
Operating System Non -Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 1mV/Div to 1 V/Div
Vertical Resolution NA bits
Coupling AC,DC,Ground
Time Base Range 0.2 microsec. to 0.2s/div
Trigger Types Vertical,CH1,LINE,Ext
Measurements Add,subtract
Frequency Analysis Feature No
In-built Frequency Counter Yes
In-built Function Generator No
Acquisition Modes Auto,Normal,TV-V,TV-H
Display Type Monochrome
Display Size 6 Inch (15.24 CM) CM
I/O Interface NA
Standard Accessories To Be Supplied 2 No of Passive probe,Power chord,Manual
Operating Temperature Range 55 Degree C
Operating Humidity (RH) 95 %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. 1016QFN05
Test Report Date 05/09/2016
Name Of The Lab SWISSCERT, Rajkot Gujarat
Warranty 1 Year
Real Time Bandwidth 30 MHz
Record Length Per Analog Channel Simultaneously Not Applicable Mega Point
Sample Rate Per Analog Channel Simultaneously Not Applicable GS/sec
Waveform Update Rate Not Applicable Waveforms/
Time Base Accuracy 3 PPM

Price Dekho Price Dekho Price List in india