× All the transactions performed on 2.0 is available here. To access Market click "Home".

Megger DET4TCR2 Digital Earth Ground Tester (MEGGER)(DET4TCR2 Clamps)

` 258,700.00

  • MRP: `290000.00

MeggerDET4TCR2clamps Digital Earth Ground Tester,the instrument provides all the functions required for ground system testing 2 pole,3 pole,4 pole, Attached Rod Technique ART,stakeless,leakage current and ground noise voltage measurement. The instrument offers a wide measurement range of 0.01to20 k, ground noise voltage measurement from 1V to 100V and ground current from 1mA to20A.Accurate results can be obtained in electrically noisy environments since the instrument is capable of rejecting noise voltages of40 V peak to peak. The DET4TCR2 is powered from rechargeable AAcells. The battery charger is built in and the instrument issupplied with an AC/DC adaptor. The Megger ground testers comply with stringent safety standards and are rated to 100 V CAT IV. They also have selectable 25 V or 50 V output for compliance with IEC61557-55IP54 rated aswell. Formore infoplease refer datasheet ofOEM. Warranty Three years on main instrument, one year on accessories, price is inclusive GST18percent.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurable Earth resistance range - Auto ranging
  • 2-pole method for resistance measurement - YES
  • 3-pole method for resistance measurement - YES
  • Number of the stakes - 4 NOS.
  • Diameter of the Stakes - 8mm cm
Other Specifications Download Specification
Display Type 3 digit LCD display
Measurable Earth Resistance Range Auto ranging
2-pole Method For Resistance Measurement YES
3-pole Method For Resistance Measurement YES
4-pole Method For Resistance Measurement YES
Number Of The Stakes 4 NOS.
Material Of The Stakes galvanised steel
Length Of The Stakes 200mm cm
Diameter Of The Stakes 8mm cm
Number Of The Test Leads 4 Nos.
Length Of The Test Leads 15m-110m-2nos 3m-1 cm
No. Of Test Leads With Clamps 2 Nos.
Length Of Test Leads With Clamps standard cm
Measuring Range1 For Earth Resistance auto 0.01Ohms to 20Kohms Ohms
Measuring Range2 For Earth Resistance auto 0.01Ohms to 20Kohms Ohms
Measuring Range3 For Earth Resistance auto 0.01Ohms to 20Kohms Ohms
Measuring Range4 For Earth Resistance auto 0.01Ohms to 20Kohms Ohms
Measuring Range5 For Earth Resistance auto 0.01Ohms to 20Kohms Ohms
Measuring Range6 For Earth Resistance auto 0.01Ohms to 20Kohms Ohms
Measuring Range7 For Earth Resistance auto 0.01Ohms to 20Kohms Ohms
Measurable Earth Resistance Resolution For Range1 0.01ohms Ohms
Measurable Earth Resistance Resolution For Range2 0.01ohms Ohms
Measurable Earth Resistance Resolution For Range3 0.01ohms Ohms
Measurable Earth Resistance Resolution For Range4 0.01ohms Ohms
Measurable Earth Resistance Resolution For Range5 0.01ohms Ohms
Measurable Earth Resistance Resolution For Range6 0.01ohms Ohms
Measurable Earth Resistance Resolution For Range7 0.01ohms Ohms
Measurable Earth Resistance Accuracy For Range1 2 3 digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range2 2 3 digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range3 2 3 digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range4 2 3 digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range5 2 3 digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range6 2 3 digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range7 2 3 digits ±% reading ± digits
Stakeless Test(Clamp On) yes
Facility To Measure Earth Voltage Available
If Yes,Measurable Earth Voltage Range 0 to 100 V ac Volts Volts
If Yes,Measurable Earth Voltage Accuracy 2 2 V %
Minimum Open Circuit Output Voltage 25/50V Volts
Low Battery Indication Available
Over Range Indication Available
If Yes,Measurable Earth Voltage Resolution NA Volts
Internal Memory NA
Type Of Battery Used In The Power Supply 8 off AA (LR6) NiMH rechargeable cells
Battery Backup Time >3000 measurements Hours
Battery Charger Provided With The Meter. Yes
Weight Of The Tester 1kg (2.2lb) grams grams
Dimensions(LXWXH) 203 mm x 148 mm x 78 mm cmXcmXcm
Provision For External SD Card No
Interface NO
Operating Temperature Range (-15C to +55C) degree celsius degree celsius
Operating Humidity Range 95RH %
All Connecting Cables And Accessories To Be Supplied Along With The Tester. Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. Regarchargeable digital 2, 3 and 4 terminal ground tester and external AC/DC adaptor,I Clamp ,V Clamp,Hard carry case Stake and wire kit (15m, 10m, 10m, 3m),calibration check PCB
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. Yes
Type Test Report No. S01103
TTC Report Date 11 January 2017
Name Of Lab Megger Instruments Limited
Address Of Lab MEGGER LIMITED UK

Price Dekho Price Dekho Price List in india