× All the transactions performed on 2.0 is available here. To access Market click "Home".

battery charger (Nes)(Nes 2)

` 13,999.00

  • MRP: `19999.00

Compatibility with battery type User Selectable - Lead acid Tubular VRLA-SMFBattery/battery bank Voltage - 12 VoltsCapacity of the battery to be chargedUser Selectable - 180AH AH Number Of Independent charging Stations - 4 Nos.Efficiency - 95..

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Compatibility with battery type (User Selectable) - Lead acid & Tubular &VRLA-SMF
  • Battery/battery bank Voltage - 12 Volts
  • Capacity of the battery to be charged(User Selectable) - 180 AH
  • Number Of Independent charging Stations - 4 Nos.
  • Efficiency - 95 %
Other Specifications Download Specification
Charger Technology Transformer Based
Compatibility With Battery Type (User Selectable) Lead acid & Tubular &VRLA-SMF
Battery/battery Bank Voltage 12 Volts
Capacity Of The Battery To Be Charged(User Selectable) 180 AH
Maximum Charger Output Current 12 Amp
Number Of Independent Charging Stations 4 Nos.
Charging Cut-off Voltage Per 12V Battery 4.5 Volts
Input Voltage Range 150 to 280vac VAC VAC
Efficiency 95 %
Ripple (Peak To Peak At Full Load) Less then 90 millivolts millivolts millivolts millivolts
Reverse Polarity Protection Yes
Short Circuit Protection Yes
Over Current Protection Yes
AC Surge Protection with MOV
Soft Start And Soft Stop Feature Without Inrush Current Yes
Over Voltage Cutoff Protection Yes
Facility For Charging Deep Discharged Battery Through Pulse Charging. Yes
Cut-in Voltage For Charging A Discharged Battery 10.5 Volts
Cut-off Voltage For Charging A Discharged Battery 14.5 Volts
Not To Charge Battery In Case One Or More Cells Are Internally Short/ Battery Voltage Less Than 10.5V Yes
Digital Display Of Output Voltage And Current Yes
LED Indication For Charging Status, Charged Condition Status And Reverse Polarity Yes
Cabinet Material CRCA Sheet
Cabinet Thickness 1.2 mm
Length Of Charging Cable For Each Station. 2 metre
Size Of Charging Cable For Each Station. 10 sq. mm
Minimum Operating Temperature 15 Degree Celsius
Maximum Operating Temperature 65 Degree Celsius
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Conformity To The Specification. Yes
Type Test Report No. 342
TTC Report Date 01/03/2017
Name Of Lab Elka leborateri
Address Of Lab Main Street Jaipur

Price Dekho Price Dekho Price List in india