Test voltages to up 10 kV and save time by trending on the spot only with Fluke ConnectCAT III 1000 V, CAT IV 600 V safety ratingWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safetySelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 VMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recallLong battery life gives the user over 750 tests between chargesAutomatic calculation of Dielectric Absorption DAR and Polarization Index PI with no additional setupGuard system eliminates the effect of surface leakage current on high-resistance measurementsLarge digital/analog LCD for easy viewingCapacitance and leakage current measurementRamp function for breakdown testingResistance measurements up to 2 TTimer settings up to 99 minutes for timed tests3-year warranty.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 1 milliamper |
Operating Temperature Range | -20 C to 50 C (-4 F to 122 F) Degree C Degree C |
Operating Humidity (RH) | 80 to 31 C decreasing linearly to 50 at 50 C % |
Power Requirements | Battery Operated |
Type Of Battery | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Test cables with alligator clips (red, black, green),Infrared adapter with interface cable,FlukeView Forms Basic CD-ROM,AC power cord,Soft carrying case,English manual,Users manual on CD-ROM,Quick reference card,Software license agreement,Registration card,FlukeView Forms installation guide,USB-IR cable installation guide |
Dimensions (H X W X L) | 269 mm x 277 mm x 160 mm (10.6 in x 10.9 in x 6.3 in) mm x mm x mm x mm x |
Weight | 3.7 kg (8.2 lb) gms gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 39456472 |
Test Report Date | 10 DEC 17 |
Name Of The Lab | FLUKE USA |
Warranty | 3 |