Molex PowerCat 6 Shielded Patch Cords are key components of the PowerCat 6 shielded end-to-end solution. Molex PowerCat 6 Patch Cords are designed to support high speed networks. The patch cable is made from high quality four pair 26 AWG stranded copper wire. Available in a range of colors and lengths, PowerCat 6 patch cords are pre-terminated with RJ45 plugs and feature anti-snag slim strain relief slip on boots..
Other Specifications Download Specification | |
---|---|
Network Cabling : The Entire Network Shall Be Based On Structured Cabling System. All UTP Cables Shall Be Connected To The Patch Panel At One-end And Information Outlets (I/O) On The Other. Factory Crimped Patch Cords Shall Be Used For Connecting PCs Through I/O Boxes And Between Patch Panel And Switch Ports. Generally 1M Patch Cords Shall Be Used For Interconnection Between Patch Panel And Switch Ports And 2M Patch Cords Shall Be Used For Connection Between I/O Box And PCs.All Fiber Cable Cores At The End Location Shall Be Terminated On Fiber Optic Smart Patch Panel Through SC/LC/MT-RJ Connectors. F/O Patch Cords (factory Crimped) Shall Be Used For Connecting F/O Ports Of The Switch To The F/O Patch Panel. Fiber Splicing Shall Be Done Wherever It Is Required To Branch Off The FOC From One Junction Point To Another. While Terminating/splicing FOC And Utmost Care Shall Be Given To Fiber Management Like Accessibility And Bend Radius Control And Compact Design. Fusion Based Splicing Technique Shall Be Applied To Limit The Attenuation Within Permissible Limit As Per Standard. Splicing With Pigtail Termination On F/O Patch Panel Shall Be Adopted At All Branched Off Locations.Care Shall Be Taken To Limit The Losses In Various Fiber Optic Components As Per Following Details:Component Loss Single Mode Fiber 1310 Nm : 0.35 – 0.4 DB/km 1550 Nm : <= 0.22 DB/km Multimode Fiber 850 Nm : 3 – 4.1 DB/km 1310 Nm : 0.6 – 1.1 DB/km Optical Connectors 0.1 – 0.75 DB Fusion Splices 0.1 DB All The Switches And Patch Panels And And Splicing Units Shall Be Housed In Suitable Enclosures. | Yes |
Fiber Optic Cable : Fiber Optic Cables Shall Be Of Single Mode (9/125 Mm) As Per ITU-T G.652standard And Shall Support Optical Source Wavelength Of 1310 And 1550 Nm. The F/O Cable Shall Be Armored With Low Water Peak Optical Fiber And Shall Be Suitable For Underground Laying. Cables Shall Be Flexible Enough To Allow Safe Bend. The F/O Cable Shall Be Of 6/12 Cores With Core Identification Mark. | Yes |
Fiber Optic Patch Panel : Fiber Optic Patch Panel Shall Have Powder Coated With Wall/rack Mounting Arrangement. The Panel Box Shall Have Enough Space To Provide Storage Of The Excess Cable. Rubber Grommets Shall Be Provided At The Cable Entry Points And For Tight Sealing. The Panel Shall Be Complete With Required Adapters And Couplers And Connectors And With Rodent Protection | Yes |
Fiber Patch Cord : Fiber Patch Cord Shall Be Used To Connect The Fiber Patch Panel And F/O Ports Of Switches. The Patch Cord Shall Be SC-SC Or SC-LC Or SC-MTRJ Type As Per Requirement. The Length Of The Patch Cord Shall Be 1 Meter Minimum. The Patch Cords Shall Conform To TIA/EIA/ITU Specification. The Patch Cords Shall Be Factory Connectorised. | Yes |
UTP Cable : All UTP Cables Shall Be Of Solid 4 Pair And PVC Insulated Category-6 Type.UTP Cables Shall Conform To TIA/EIA Standards. | Yes |
UTP Information Outlets (I/O) : All UTP Cabling Shall Be Terminated At The Node End On To A Single Port I/O Box. The I/O Box Shall Be Of Plastic And Shall Be Suitable For Termination Of Cat-6 UTP Cable. The I/Os Shall Have Spring Shuttered Front Access For The Cable To Prevent Entry Of Dust. The Keystone Jack (RJ 45) Shall Be Of High Performance Type With Easy Snap-in And Removal And High Plug Insertion Life. The I/O Boxes Shall Conform To Relevant TIA/EIA Standards. | Yes |
UTP Patch Cord : All Patch Cords Shall Be Of Cat-6 UTP Cable, With RJ45 Connectors At Both Ends And Conforming To TIA/EIA Standards. The Patch Cords Shall Be Of Standard Length (2M). However For Connecting Patch Panel To Switch Ports, Smaller Patch Cords Of 1M Length Shall Be Provided. All Patch Chords Shall Be Factory Crimped | Yes |
UTP Patch Panel : The Patch Panel Shall Be On Steel Chassis With Rack Mounting Arrangement And Cable Management Facility. All Cables Shall Be Terminated Through Insulation Displacement Connectors Mounted On The Printed Circuit Board And Conforming To Cat- 6 EIA/TIA Standards. The Patch Panel Shall Be Of 24 RJ-45 Ports Capacity. | Yes |