Insulation Resistance up to 10T Short-Circuit Current up to 5mA Wide Test Voltage from 250V to 5000V Diagnostic Insulation Tests IR, PI, DAR, DD, SV, RAMP Breakdown and Burn modes, Capacitance, Leakage Current Wireless communication by Bluetooth for transferring and showing real-time data to PC and Android device Memory and Logging functions Filter function reduces noise interference for obtaining stable measurements Large back light display with Bar-Graph indication Robust design for field use with IP65 lid closed Powered by rechargeable battery Safety Standard IEC 61010-1 CAT 600V.
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Live circuit indicator 30 V to 600v ACDC,50 Hz |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | 0-40 Degree C |
Operating Humidity (RH) | 85 OR Less % |
Power Requirements | Battery Operated |
Type Of Battery | Lead Acid Battery |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord), 8019 (Hook type prod), 8327EU (Power adaptor 15V/1A), 9171 (Hard case), Instruction manual |
Dimensions (H X W X L) | 130X250X208 mm x mm x |
Weight | 4000 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | HOIL-E-01-18-616-01 |
Test Report Date | 01-01-2018 |
Name Of The Lab | HARIOM INSTRU-LABS |
Warranty | 1 |