Keysights Infiniium 90000 Series oscilloscopes offer the industrys lowest noise floor and most accurate real-time jitter measurements available on scopes of this bandwidth class. Complete with full-bandwidth probing solutions and hardware accelerated de-embedding and equalization techniques, Keysight oscilloscopes are the best oscilloscope solution for todays demanding high-speed measurements. Choose from the industry widest range of complete applications for the DSO90000A Series to ensure compliance to the leading industry standards, including SATA,PCI EXPRESS,Ethernet,USB,and more.Comprehensive setup wizards and full automation of the required testing take the guesswork out of demonstrating compliance quickly.Get further insight with our protocol and analysis decode available on PCI EXPRESS, SATA and USB. DSO90404A is 4GHz bandwidth,20GSa/s Sampling rate,20Mpts standard record length,3 year standard warranty.Refer OEM datasheet for detail specification. Prices indicated includes GST..
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Windows |
Bandwidth Upgradability | Yes |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | Yes |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 1mV/Div to 1 V/Div |
Vertical Resolution | 8 bits |
Coupling | DC |
Time Base Range | 5 ps/div to 200 s/div real-time |
Trigger Types | Edge, Edge Transition, Glitch, Line, Pulse Width, Runt, timeout, pattern, state, setup/hold, window, video, zone |
Measurements | Peak to peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, preshoot, upper, middle, lower, Rise time, fall time, period, frequency, positive width, negative width, duty cycle, burst width, Tmin, Tmax, Tvolt, channel to channel delta time, FFT frequency, FFT magnitude, FFT delta frequency, FFT delta magnitude and many more. |
Frequency Analysis Feature | No |
In-built Frequency Counter | No |
In-built Function Generator | No |
Acquisition Modes | Normal, Peak Detect, Average, High Resolution, Segmented Memory |
Display Type | Colour |
Display Size | 12.1 inch color XGA TFT LCD with touch screen, 256 level intensity graded display, Annotation Up to 12 labels, with up to 100 characters each CM |
I/O Interface | USB, LAN, LXI Compliance |
Standard Accessories To Be Supplied | USB Mouse, Keyboard, User guide, accessory pouch, power cord |
Operating Temperature Range | 5 to 40 Degree C Degree C |
Operating Humidity (RH) | up to 95% relative humidity at 40 degree C % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | NTH(SR)EL(C)/2013/328F |
Test Report Date | 13/09/2013 |
Name Of The Lab | NTH Taramani, Chennai |
Warranty | 3 Year |
Real Time Bandwidth | 4000 MHz |
Record Length Per Analog Channel Simultaneously | 20 Mpts on 4 channels or 40 Mpts on 2 channels Mega Point |
Sample Rate Per Analog Channel Simultaneously | 20 Gsa/s GS/sec |
Waveform Update Rate | 400,000 waveforms per second Waveforms/ |
Time Base Accuracy | 1 PPM |