Keysight N5171B EXG Signal Generator offers deliver unmatched performance in five key categories phase noise and spectral purity, bandwidth, EVM, ACPR, and output power. N5171B with option 506 has frequency range from 9KHz to 6GHz with analog modulation option UNT. Phase noise less than 120dBc/Hz and output power upto 20dBm at 1GHz. Perform basic parametric testing of components and functional verification of receivers with industry-leading output power. Standard 3 year warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent..
Other Specifications Download Specification | |
---|---|
Type | RF Signal Generator |
Frequency Range | 9 KHz to 6 GHz |
Frequency Resolution | 0,1 Hz |
Ageing Rate For Reference Frequency (As Declared By OEM) | Less than 2 PPM/Year |
Temperature Stability For Reference Frequency | Less than 2 PPM |
SSB Phase Noise At 1GHz,on 20KHz Offset (dBc/Hz) | less than -105 dBc |
Harmonics At 3 GHz Level At 0 DBm | less than -30 dBc |
Non Harmonics (>10 KHz Carrier Offset) | less than -60 dBc |
Non Harmonics (>50 KHz Carrier Offset) | NA dBc |
Reverse Power Protection | 50V DC, 20W at 6GHz Watt |
Minimum Output Level | -120 dBm |
Maximum Output Level | +13 dBm |
Output Level Resolution | 0,1 dB |
Total Accuracy Forall Specified Output Level At 25 Degree C In Continuous Wave Mode | ±0.8 dB dB |
VSWR On All Operating Frequencies | 1.9 |
Memory (Minimum Storage Settings) | 1000 |
Amplitude Modulation (AM) Operating Modes | Internal & External |
Minimum Amplitude Modulation Frequency (3 DB), F > 100 KHz | DC or 10Hz Hz |
Maximum Amplitude Modulation Frequency (3 DB), F > 100 KHz | 50KHz KHz |
Modulation Depth | 0 to 100% % |
Resolution Of AM | 0.1% |
AM Distortion At 1 KHz | < 2 |
Frequency Modulation (FM) Operating Modes | Internal & External |
Minimum Frequency Modulation Frequency (-3 DB) Standard | DC or 1Hz |
Maximum Frequency Modulation Frequency (-3 DB) Standard | 7MHz |
Minimum Frequency Deviation | 1 MHz |
Maximum Frequency Deviation | 40 MHz KHz |
Resolution Of FM | 0.025% of deviation or 1 Hz |
Setting Error (at AF=1 KHz And 50% Max. Deviation) For FM | < 0.4 |
Phase Modulation | Available |
If Available, Phase Modulation Operatinf Mode | Internal & External |
Minimum Phase Deviation | 1.25 Rad Radians |
Maximum Phase Deviation | 20 Radians Radians |
Resolution Of Phase Modulation | 1 % |
Setting Error (at AF=1 KHz) For Phase Modulation | < 0.2 (typ) [1 kHz rate |
Internal Modulation Generator For AM/FM/PM | 0.1 Hz to 2 MHz tunable to 3 MHz with resolution of 0.1 Hz |
Pulse Modulation | Not-Available |
If Available, Pulse Modulation Operating Modes | NA |
Rise And Fall Time | NA ns |
On/Off Ratio | NA dB |
Minimum Pulse Width | NA ns |
Input Level | NA |
RF Digital Sweep Range And Width | 9KHz to 6GHz |
RF Digital Sweep Time Range | 100 μs to 100 s |
RF Analog Sweep | Not-Available |
If Available, RF Analog Sweep Range And Width | NA |
RF Analog Sweep Time Range | NA |
Pulse Generator | Not-Available |
If Available, Pulse Generator Operating Mode | NA |
Pulse Width | NA |
Pulse Delay | NA |
Pulse Period | NA |
Vector Modulation | Not-Available |
Internal Base Band Generator Bandwidth | NA MHz |
Arbitory Waveform Memory | NA Mega samples |
Modulation | NA |
Error Vector Magnitude (EVM) | 0 % |
Phase Modulator | Not-Available |
If Available, Range Of Modulating Signal (Wide Mode) | NA |
If Available, Range Of Modulating Signal (Narrow Mode) | NA |
Interface Available | USB, LAN, GPIB |
Standard Acessories (To Be Supplied) | Country-specific power cord Documentation set (CD-ROM) 3-year return-to-Keysight warranty |
Power Requirements | 230 V +/-10% AC, 50 Hz +/- 3% |
Operating Temperature Range | 0 to 55 degree C Degree C |
Operating Humidity (RH) | Relative humidity at 95%, 40 degree C % |
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. | Yes |
Test Report No. | NTH(SR)/EL(C)/2013/024L |
Test Report Date | 04/02/2013 |
Name Of The Lab | NTH Taramani, Chennai |
Warranty | 3 Years |