1. Filtering efficiency 94 against Solid Liquid particles Complies EC type test requirement based on EN 1492001 by European notitied body, IFA 0121 , Germany. 2. Maximum Use Concentration10 x OEL For Particulates. 3. High technology filter media with micro fine fibers electro static charge gives maximum filtering efficiency. 4. Use for Protection against solid Liquid or oil based particles - tested for mean particle size 0.6 micron as per CE Norms and Protection against nuisance level of organic vapour odours. 5. Max. Weight 21 Grams. 6. One Way Exhalation Vent Valve Unique butterfly wings design provides maximum breathing comfort. 7. Expected Time of Delivery of products at clients location is subjected to the current availability of the SKU in stock and transportation delay. 8. Suggested applications Pharmaceutical, Drilling, Construction, Battery, Tyre, Sand blasting, Fertilizer, Soldering, Cement, Foundries, Textile, Woodworking, Grinding, Ceramics, Engineering, Bagging etc..
Other Specifications Download Specification | |
---|---|
Conformity To Indian Standard | IS: 14166 (Latest) |
ISI MARKED | No |
CML. NO. (If ISI Marked) | NA |
Flammability | Self -Extinguishing |
Construction | Single integral Unit |
Material | Non Woven Fabric |
Inner Mask | Integral with face Mask |
Adjustable Head Harness | Integral with face Mask |
Eyepieces & Visors | Single Visor Integral with face Mask |
Connectors | Integral with face Mask |
Type Of Connectors | Standard Thread connection |
Inhalation & Exhalation Valves | Integral with face Mask |
Check Valves | Integral with face Mask |
Lens Wiper | Integral with face Mask |
Speech Diaphragm Assembly | Integral with face Mask |
Cleanable | Yes |
Disinfectable | Yes |
Compatibility With Skin | Should not cause irritation or adverse effect to health |
Maximum Average Inward Leakage (% Of Inhaled Air) | 0.004 % |
Maximum Breathing Resistance While Inhalation Tested At Continuous Flow Of 160 1/min | 0.5 mbar |
Maximum Breathing Resistance While Exhalation Tested At Continuous Flow Of 160 1/min | 3 mbar |
"Maximum Average Carbon Dioxide Content Of The Inhalation Air (% By Volume)" | 0.4 % |
Mass Of Single Mask | 21 gram |
Availability Of Test Report From NABL/ ILAC Accredited Or Central Government Lab To Prove Conformity Of Products To The Specification. | NA |
Test Report No. | NA |
Test Report Date | NA |
Name Of The Lab | NA |
Address Of The Lab | NA |