44GHz Spectrum OR Signal Analyzer - Keysight - N9010B (keysight technologies)(N9010B-544)

` 4,411,958.00

  • MRP: `5190535.00

The EXA is your first, best choice when you need maximum value in signal analysis up to millimeter-wave frequencies. It helps you find the answer faster, whether youre seeking tighter design margins or shorter test times. EXA N9010B-544 HAVE FREQUENCY RANGE FROM 10HZ TO 44GHZ, 25MHZ STANDARD ANALYSIS BANDWIDTH, LESS THAN 152dBm DANL AND LEASS THAN 170dBc/Hz PHASE NOISE AT 1GHz. WITH MULTI-TOUCH USER INTERFACE. With the X-Series, you can perform most operations in two steps or less using the streamlined multi-touch user interface. With X-Series signal analyzers, PowerSuite provides one button measurements of channel power,ACP, OBW, and more. For added flexibility, you can quickly and easily reconfigure the CXA with measurement applications that it changing testing requirements through license-key upgrades optionally. Standard 3 Year Warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Frequency Range - 9 kHz to 40 GHz
  • Aging rate of spectrum analyzer frequency: Better than 1x10-6 /Year - Yes
  • Frequency counter Resolution(min.) - 1 Hz
  • Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz - Yes
  • Sweep time @span = 0 Hz - 10 micro S to 2000 S
Other Specifications Download Specification
Description Of The Item Spectrum analyzers 40GHz
Frequency Range 9 kHz to 40 GHz
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year Yes
Frequency Counter Resolution(min.) 1 Hz
Frequency Span 0Hz(zero span),1kHz to 3GHz
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz Yes
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc Yes
Sweep Time @span >or= 1 KHz 2.6mS to 1000S
Sweep Time @span = 0 Hz 10 micro S to 2000 S
Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps
Video Bandwidth 10Hz to 1 MHz in steps
Amplitude : Max Input Level For Protection +30 dBm
Amplitude : Max Input Level For Measurement +20 dBm
Amplitude :level Measurement Uncertainity <or=1 dB
Average Noise Level Displayed 300HzRBW,10Hz VBW:
Markers Normal and delta
Trigger Free run, video, External
Display TFT Colour display
Interface USB and LAN
Measurement Features CN ratio,AM,time domain power measurement,channel power measurement,Phase noise measurement,TOI,OBW
Software For Transfer Of Screen Shot/measurement Data To PC Yes
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. NA
Frequency Range For 2port Vector Network Analyzer 2 MHz to 3 GHz
Frequency Resolution (CW ON) For 2port Vector Network Analyzer NA Hz
Return Loss For 2port Vector Network Analyzer NA dB
VSWR For 2port Vector Network Analyzer NA
Cable Loss For 2port Vector Network Analyzer NA dB
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB NA
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible NA
Phase Range For 2port Vector Network Analyzer NA degree
Phase Resolution For 2port Vector Network Analyzer NA deg
RF Output Port For 2port Vector Network Analyzer Type N, female, 50Ohm
Dynamic Range For 2port Vector Network Analyzer NA dB
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. NA
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible NA
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available NA
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared NA
Operating Temperature 5 to 40 degree C & 80 RH 40 degree C
Power Requirement 230 +- 10 VAC, 50Hz
Warranty 3 years
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works yes
One Set Of Operation And Maintenance Manual Shall Be Supplied yes
Standard Accessories Shall Be Supplied yes
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications yes
Test Report No NTH(SR)/EL(C)/2013/024H
Test Report Date 04/02/2013
Name Of Lab National Test House
Address Of The Lab NTH Taramani, Chennai