Hardware Form Factor of Unified/NAS System -4U OR LESS RU, RAID Type - RAID 5/6, Number Of Front end Port - 4,.
Other Specifications Download Specification | |
---|---|
Type Of Storage | NAS |
Usable Capacity Of Storage System | 48 TB |
Hardware Form Factor Of Unified/NAS System | 3U RU |
Type Of Drives | NL SAS |
RAID Available | Yes |
If Yes ,RAID Type | RAID 5,6, 10, 50, 60 |
Type Of Front End Ports | 10G |
Number Of Front End Port | 4 |
Speed Of Front End Ports In Gbps | 10G Gbps |
Type Of Back End Ports | SAS 12G |
Number Of Back End Port | 4 |
Speed Of Back End Ports In Gbps | 12 Gbps |
Number Of Controllers Available In Storage System | 2 |
Supported Global Cache | Yes |
Total Configurable Cache Per Controller. | 32 GB |
Total No Of Drive Slots In The Storage System | 16+16 |
No Drive Slots Populated In The Storage System | 12 |
Capacity Of Single Drive Populated With The Storage System | 4TB GB |
No Of Drive Slot Available For Scalability | 128 |
No Of Snap Shot Copies | 65536 |
Remote Replication | Yes |
Synchronous Replocation Support | No |
Asynchronous Replication Support | Yes |
No Of Volume Supported | 1000 |
Three Way DR Capability | No |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | NFS,CISF,FCoE , iSCSI - NFS , ISCSI |
Hot Spare Available | Yes |
If Yes ,No Of Drives Per Hot Spare | 2 |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | Yes |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | Yes |
Network Switch | Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | L3 MANAGED SWITCH 10G |
Hardware Form Factor Of Network Switch | 2U OR LESS RU |
Number Of Network Switches Provided With Storage System | 2 |
Number Of Active Ports In The Network Switch | 24 |
Operating System Platforms Supported | Linux, windows |
Clustering Supported | Yes |
Deduplication | No |
Compression | No |
Operating Temp Range | 5-40 Degree C |
Storage Temp Range | 5-40 Degree C |
Operating Humidity (Rh) | 8-90 % |
Storage Humidity (Rh) | 8-90 % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | R-41007323 |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | 314.86 Watt |
Max Power Consumption Of System | 501.40 Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 5 Year |
Type Of Clustering | Host Based |