Buy this Microtek NM72MX2KK11 2KVA UPS to protect your computer from unexpected mishaps. It not only saves your expensive device but also prevents your operating system from getting corrupt at an event of a power cut. It is not very heavy but its structural design is such that it occupies very limited space.Size and DimensionsWith 421 190 336L W H mm dimensions, Microtek NM72MX2KK11 2KVA UPS is a sleek and compact power backup solution which is available in a classic black tone, adding a touch of elegance to your work place.Technical FeaturesMicrotek NM72MX2KK11 2KVA UPS boasts high frequency and double conversion online technology. In case of low voltage of around 150V and high voltage of around 290V, the UPS is capable of correcting it to 230V 9. The capacity of its internal battery will remain at the same level if the main voltage drops. There is a Smart Boost function in the UPS which takes the low voltage back to its normal range whereas, the Smart Buck or A.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 2 KVA |
Technology | MOSFET-PWM with inbuilt isolation transformer |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V 1 sinewave,50Hz |
Backup Time | 30 Minutes |
Minimum VAH | 3200 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 0 % |
Overall Efficiency | 90 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | With |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | NTH(SR)/EL(C)/2014/290B |
Type Test Certificate Date | NTH(SR)/EL(C)/2014 |
Name Of Lab | Central Govt. /NABL/ILAC |
Address Of Lab | DELHI |
Supply & Commissioning | IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C |
Warranty | 1 Years |