without battery 40 kva online UPS KEOR T has been designed with advanced technologies and the latest generation components IGBT based rectifier and IGBT based inverter with multi DSP controller realized to satisfy both users and installers for operational needs and performance. This UPS aims to be functional, safe and very easy to install and use. Legrand has studied the best way to reconcile high-tech performance and ease of use,making user friendly technologically advanced products. KEOR T supplies the maximum protection and power quality for any type of IT loads, light industrial, heavy industrial..
Other Specifications Download Specification | |
---|---|
Rating In KVA | 40 KVA |
Technology | IGBT-PWM with inbuilt isolation transformer |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | 3 phase 400 V 1 with alternative user setable setting of 380V+-1,50Hz |
Backup Time | 120 Minutes |
Minimum VAH | 0 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | THD % |
Overall Efficiency | 90 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | With |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | NTS/PPTL/UPS-303/18 |
Type Test Certificate Date | 10/09/2015 |
Name Of Lab | NISAKI TECHNOLOGY SERVICES |
Address Of Lab | NO. 46 PARK ROAD,2ND MAIN,10TH CROSS,WILSON GARDEN,BANGLORE-5600027 |
Supply & Commissioning | UPS WITH BATTERIES BANK |
Warranty | 2 Years |