Digital Clamp tester 0-30 Amp. AC DC , AUTO RANGING DIGITAL CLAMPMETER - 600 A DC / AC TRMS AND 600 A DC / AC TRMS , Features Power One 9 V BatteryBattery Life 150 hours typicalLow Battery IndicationJaw Opening Cable Dia 55mm max. AC Current 600 A, 1000AAC Voltage 6V, 60V, 600V auto manual ranging DC Current 600 A, 600 A DC Voltage 600 mV, 6V, 60 V, 600 V Auto Manual Ranging Resistance 600 , 6 k, 60 k, 600 k, 6 M, 60 M Auto Manual Ranging Frequency 9.999 Hz 999.9 KHz Auto Ranging Capacitance 40 nF, 400 nF, 4 F, 40 F auto - ranging Sp.Function Audible continuity, Diode Test Function Weight 410 gms Including Battery approx Accessories Supplied with a Pair of Test Leads, Battery installed, Inst.Manual Carrying Case.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 55MM |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | 20C 1000C / 0F 1832F Degree C |
Operating Humidity (RH) | 40 % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
Standard Accessories Supplied With The Equipment | Supplied with a Pair of Test Leads, Battery (installed), Inst.Manual & Carrying Case |
Dimensions (H X W X L) | 238 x 90 X 48mm (approx) mm x mm x |
Weight | 300 G (APPROX) gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | ERTL(W)2003 E&S257 |
Test Report Date | 30.01.2004 |
Name Of The Lab | ERTL(WEST) |
Warranty | 1 Year |