× All the transactions performed on 2.0 is available here. To access Market click "Home".

keor T series 60kva 3 phase - 3phase online ups Without battery keor T series (numeric -legrand)(60kva 3PH- 3PH Online ups keor t Series)

` 941,990.00

  • MRP: `1550000.00

Industrial 60 kva on line UPS KEOR T has been designed with advanced technologies and the latest generation components IGBT based rectifier and IGBT based inverter with multi DSP controller realized tosatisfy both users and installers for operationalneeds and performance. This UPS aims to be functional, safe and very easy to install and use. Legrand has studied the best way to reconcile high-tech performance and ease of use,making user friendly technologically advanced products. KEOR T supplies the maximum protection and power quality for any type of IT loads, light industrial, heavy industrial..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - 3 phase 400 V 1 with alternative user setable setting of 380V+-1,50Hz
  • Minimum VAH - 0 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 60 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power 3 phase 400 V 1 with alternative user setable setting of 380V+-1,50Hz
Backup Time 30 Minutes
Minimum VAH 0 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) THD %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. NTS/PPTL/UPS-303/18
Type Test Certificate Date 10/09/2015
Name Of Lab NISAKI TECHNOLOGY SERVICES
Address Of Lab NO. 46 PARK ROAD,2ND MAIN,10TH CROSS,WILSON GARDEN,BANGLORE-5600027
Supply & Commissioning UPS WITH BATTERIES BANK
Warranty 2 Years

Price Dekho Price Dekho Price List in india