× All the transactions performed on 2.0 is available here. To access Market click "Home".

Digital Rebound Meter (N and M)(NM-A2069)

` 149,499.00

  • MRP: `175000.00

CONCRETE TEST HAMMER, MICROPROCESSOR OPERATED, ENTIRELY DESIGNED AND MANUFACTURED WITH ADVANCED TECHNOLOGY, PERFORMS BASIC CONCRETE TESTING WITH CONTINUOUS AUTOMATIC RECORDING OF ALL PARAMETERS IN ACCORDANCE WITH EN 12504-2 SPECIFICATIONS, REGISTER AND PROCESS DATA AND THEN TRANSFER THEM TO A PC THE UNIT CONSISTS OF THE STANDARD MECHANICAL MODEL, BUT EQUIPPED WITH AN ELECTRONIC TRANSDUCER THAT MEASURES THE REBOUND VALUES AND SUPPLIES AUTOMATICALLY THE RESULTS ON A GRAPHIC DISPLAY.MEASURING RANGE 10 120 N/MM2- INTERFACE RS232- POWER SOURCE 6 RECHARGEABLE BATTERIES AA NIMH 2000MA- BATTERY LIFE 60 HOURS WITH AUTOMATIC SHUTDOWN- OPERATING TEMPERATURE -10C 60C SUPPLIED COMPLETE WITH DATA TRANSFER SOFTWARE, DATA TRANSFER CABLERS 232, BATTERY CHARGER, ABRASIVE STONE, CARRYING CASE.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 4000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 3 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 4000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.005 %
AC Current Measurement 3 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 3 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range 1 to 100 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -40 to 400 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Available
True RMS AC Voltage Band Width 100
Safety Rating Category II 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range 95
Operating Humidity (RH) 85
Power Requirements 230 V +-10 AC, 50 Hz +- 3 through Adaptor
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 2x3.5
Total Voltage Of Battery 7
Standard Accessories Supplied With The Equipment Standard
Dimensions (H X W X L) 168x22x50 mm x mm x
Weight 250 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 21454
Test Report Date 21.02.2017
Name Of The Lab Star Labs
Warranty 1 Year

Price Dekho Price Dekho Price List in india