VSP G400 Unified with redundant SAN and NAS controllers, 128GB Cache, 4 x 16Gbps FC Ports, 4 x 10Gbps Ports, 4 x 12Gbps SAS Backend Ports, 6 x 480GB SSD Drives, 10 x 1.8TB SAS Drives, 9 x 6TB NLSAS Drives, 2 x SAN Switches each with 12 x 16Gbps FC Ports, Heterogeneous storage virtualization, Snapshots, clones and 5Yrs Support.
Other Specifications Download Specification | |
---|---|
Type Of Storage | Unified |
Usable Capacity Of Storage System | 45 TB |
Hardware Form Factor Of Unified/NAS System | 8U RU |
Type Of Drives | SSD |
RAID Available | Yes |
If Yes ,RAID Type | 1+0, 5 and 6 |
Type Of Front End Ports | FC, iSCSI and NAS |
Number Of Front End Port | 8 |
Speed Of Front End Ports In Gbps | 16Gbps and 10Gbps Gbps |
Type Of Back End Ports | SAS |
Number Of Back End Port | 4 |
Speed Of Back End Ports In Gbps | 12 Gbps |
Number Of Controllers Available In Storage System | 2 |
Supported Global Cache | Yes |
Total Configurable Cache Per Controller. | 64 MB |
Total No Of Drive Slots In The Storage System | 480 |
No Drive Slots Populated In The Storage System | 25 |
Capacity Of Single Drive Populated With The Storage System | 1.8TB SAS, 6TB NLSAS and 480GB SSD GB |
No Of Drive Slot Available For Scalability | 455 |
No Of Snap Shot Copies | 255 |
Remote Replication | Yes |
Synchronous Replocation Support | Yes |
Asynchronous Replication Support | Yes |
No Of Volume Supported | 1024 |
Three Way DR Capability | No |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | FC, iSCSI, NFS and CIFS |
Hot Spare Available | Yes |
If Yes ,No Of Drives Per Hot Spare | 3 |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | Yes |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | Yes |
Network Switch | Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | FC |
Hardware Form Factor Of Network Switch | 1U RU |
Number Of Network Switches Provided With Storage System | 2 |
Number Of Active Ports In The Network Switch | 12 |
Operating System Platforms Supported | Windows Server, Enterprise LINUX, Solaris, IBM AIX, HP-UX |
Clustering Supported | Yes |
Deduplication | Yes |
Compression | Yes |
Operating Temp Range | 10 to 40 degrees Degree C |
Storage Temp Range | 10 to 40 degrees Degree C |
Operating Humidity (Rh) | 8 to 80 Percent % |
Storage Humidity (Rh) | 8 to 80 Percent % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | R-41046221 |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | 2.5KVA Watt |
Max Power Consumption Of System | 6.8KVA Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 5 Year |
Type Of Clustering | Host Based/OS Based |