The X-VS intraoral sensor offers extraordinary performance, practical ergonomics and high technology, offering a perfect balance between comfort and cutting-edge technology. The X-VS is impact and dust-resistant, is certified IP67 water-resistant and can be used with all X-ray systems.The X-VS means real-time diagnostics, direct USB plug-and-play connection, high definition and immediate results. The X-VS uses iRYS, the all-in-one software ideal for diagnostics, communication and management of intraoral imaging perfect for storing, managing and printing images in perfect synchronism with any other devices already in the surgery...
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Single phase |
Display Type | LCD Backlit |
Display Mode | 3 |
Number Of Current Channels | 2 Nos. |
Number Of Voltage Channels | 2 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 2 Volts |
Measurable Voltage Accuracy | 2 |
Measurable Voltage Resolution | 230 Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 10 Ampere |
Measurable Current Accuracy | 1 |
Measurable Current Resolution | 50 Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 2 KW |
Power Accuracy | 1 |
Power Resolution | 50 Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 50 Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | 21 |
Resolution In Measurement Of Total Harmonics Distortion | 21 |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 20 |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | 2 |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | 5 |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | 2 |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 5 |
Measurable Crest Factor Accuracy | 1 |
Measurable Crest Factor Resolution | 10 |
Screen Memory | 20 |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 0 MB |
Type Of Battery Used | 30 |
Battery Backup | 4 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 2500 Grams |
Dimensions(LXWXH) | 350x250x300 cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 95 degree celsius |
Operating Humidity | 85 % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Standard |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | Cat III |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 32568 |
TTC Report Date | 15.06.2017 |
Name Of Lab | City Centre Lab |
Address Of Lab | Dehradun |
Interface | Yes |