Dual DC Power Supply is designed as a Constant Current CC and Constant Voltage CV source for use in laboratories, industries and field testing. With compact size, light weight and low power loss, it provides DC output voltages for Analog and Digital testing.The DC output 0-30 V can be adjusted, with coarse and fine controls. Current limit is adjustable from 0-1A. DC output 5V can be adjusted between 4.8 V - 5.2 V. Over loading is indicated by LED. After crossing the specified limit a audible beep will sound.A 3-digit display for voltage 3 -digit for current is provided to read the values. These two parameters can be switched to display either voltage or current..
Other Specifications Download Specification | |
---|---|
DC Voltage Output Rating | 0 to 30 Volt |
DC Current Output Rating | 0 to 4 Ampere |
Maximum Power | 120 Watt |
Load Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 2 mV |
Load Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 1.5 mA |
Line Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 1 mV |
Line Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 0.1 mA |
Over Voltage Protection Accuracy | +- 0.5 + 0.5 V |
Over Voltage Protection Response Time | less than 10 milli sec |
Ripple And Noise Voltage (20 Hz To 20 MHz) | less than 1 mVrms less than 4 mVpp |
Ripple And Noise Current (20 Hz To 20 MHz) | less than 4 mArms |
Readback Voltage Accuracy | 0.05 + 10 mV |
Readback Current Accuracy | 0.15 + 4 mA |
Readback Voltage Resolution | 1 mV |
Readback Current Resolution | 0.1 mA |
Operating Temperature | 40 Degree C |
Gperating Humidity (RH) | 80 % |
PC Interface | USB |
Dimensions | W 196 H 80 D 262 mm x mm x |
Weight | GPIB gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | STPL/PS/1212 |
Test Report Date | 20-12-17 |
Name Of The Lab | STPL Indore |
Warranty | 1 Year |