× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital multimeter (kusam meco)(km 257)

` 12,400.00

  • MRP: `14600.00

3-5/6 DIGIT 6000 COUNTS DIGITAL MULTIMETERWITH EF-DETECTION PC INTERFACE.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 6000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 6000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.005 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 100 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 100 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range .01 to 1000 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -50 to 1000 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Available
True RMS AC Voltage Band Width 100
Safety Rating Category II 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range 0C to 40C
Operating Humidity (RH) 70
Power Requirements 230 V +-10 AC, 50 Hz +- 3 through Adaptor
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 1.5V AAA battery x 2
Total Voltage Of Battery 3v
Standard Accessories Supplied With The Equipment Test leads pair, Carrying Case, Batteries installed, Users Manual & Banana plug K-Type Thermocouple
Dimensions (H X W X L) 161(L) X 80(W) X 50(H) mm mm x mm x
Weight 340 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 5667988
Test Report Date 1/11/17
Name Of The Lab kusam meco
Warranty 1 Year

Price Dekho Price Dekho Price List in india