× All the transactions performed on 2.0 is available here. To access Market click "Home".

Torsion Testing Machine (DUO)(DMC-TTM-10)

` 638,900.00

  • MRP: `735000.00

Torsion Testing Machine.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Indication must be in mm Hg Or kPa on Reference manometer. - YES mm Hg or kPa
  • Min.uncertainty of reference manometer. - 0.8 mm Hg/0.1 kPa mm Hg or kPa
  • Reference manometer be able to measure pressure upto atleast 300 mm Hg. - YES
  • Shall measure and report value of maximum mean error of measurement and maximum experimental standard deviation - YES
  • Min. resolution/readability of Reference manometer - 0.1 mm Hg
Other Specifications Download Specification
Purpose Of Sphygmomanometer Testing Kits(Reference Manometer). To test sphygmomanometer within the accuracy of 1mm of Hg mm
Indication Must Be In Mm Hg Or KPa On Reference Manometer. YES mm Hg or kPa
Min.uncertainty Of Reference Manometer. 0.8 mm Hg/0.1 kPa mm Hg or kPa
Reference Manometer Be Able To Measure Pressure Upto Atleast 300 Mm Hg. YES
Shall Pass Leak Test At 450 Mm Hg. YES mm Hg
Shall Measure And Report Value Of Maximum Mean Error Of Measurement And Maximum Experimental Standard Deviation YES
Reference Manometer Shall Able To Measure Rapid Exhaust Time Of The EUT. YES
Reference Manometer Shall Have A Integral Pressure Generator Generating Upto 500 Mm Hg. YES
Min. Resolution/readability Of Reference Manometer 0.1 mm Hg
Reference Manometer Shall Have A Provision For Measuring 10 Samples (EUT) At A Time. YES
Pressure Measuring Device Shall Confirm Cl.4.9 Of IS:3390/1988. YES
Equipment Or Calibrator To Calibrate The Sphygmomanometer Shall Confirm The IS :3390/1981 YES
All The Gazette Of India Related To Legal Metrology Issued Time To Time Are Applicable To The Specification As Well As To The Product. YES
As Per The Gazette Of India Extraodinary,The Legal Metrology Act 2009,cl.22, Approval Of Model Before Manufacturing And Cl.23.Prohibition On Manufacture,repair Or Sale Without Licence For Product Shall Be Applicable On Manufacture Of Measuring Instrument. YES
Reference Manometer Shall Have NPL Calibration Certificate With Their Stamp And Seal And Shall Be Provided With Each Equipment As Standard And Also Available With Manufacturer For Verification Of The Product. YES
Availability Of Type Test Reports Of The Product From Central Govt/NABL/ILAC Accredited Lab Showing Compliance To The Specification YES
Test Report And Approvals To Be Furnished To The Buyer On Demand. YES
Test Reports No. PICL/QMS/0218/2863
Test Reports Date 25/04/2017
Name Of The Labs AIAB PROGRESSIVE LAB, 150 FT RING ROAD, RAJKOT GUJARAT
Product Code Available On Supplier Website NO
Product Code No NA

Price Dekho Price Dekho Price List in india