30 mhz analog oscilloscope with component tester (scientech)(scientech 801c)

` 23,900.00

  • MRP: `30000.00

Easy Scope is a new trend Oscilloscope with Component Tester and a digital touch. The Digital Readout back lit Color LCD displays Volts/div. and Time/div. settings.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Non -Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Analog
Operating System Non -Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 500mV per Div to 10 V/div
Vertical Resolution NA bits
Coupling ac,dc, gnd
Time Base Range 0.5 micro sec to 0.2 sec
Trigger Types level
Measurements na
Frequency Analysis Feature No
In-built Frequency Counter No
In-built Function Generator No
Acquisition Modes na
Display Type Monochrome
Display Size 140 mm CM
I/O Interface na
Standard Accessories To Be Supplied Probe, power cord
Operating Temperature Range 40 Degree C
Operating Humidity (RH) 80 %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. STPL/171202
Test Report Date 15-12-17
Name Of The Lab STPL, Indore
Warranty 1 Year
Real Time Bandwidth 30 MHz
Record Length Per Analog Channel Simultaneously not applicable Mega Point
Sample Rate Per Analog Channel Simultaneously na GS/sec
Waveform Update Rate NA Waveforms/
Time Base Accuracy 0.05 PPM