DELLEMC UNITY 400, TYPE OF DRIVE-SSD,SAS,NL-SAS, De-Duplication-LICENSES PROVIDED, De-Duplication-LICENSES PROVIDED,.
Other Specifications Download Specification | |
---|---|
Type Of Storage | Unified |
Usable Capacity Of Storage System | 45 TB |
Hardware Form Factor Of Unified/NAS System | 4U RU |
Type Of Drives | NL SAS |
RAID Available | Yes |
If Yes ,RAID Type | Raid 10,5/6 |
Type Of Front End Ports | 4 X 16 GB FC 4 x 10 GbeBaseT |
Number Of Front End Port | 4 FC, 4 iSCSI |
Speed Of Front End Ports In Gbps | 16 Gb FC, 10g iSCSI Gbps |
Type Of Back End Ports | 4 x 12 Gb SAS |
Number Of Back End Port | 4 x 12 Gb SAS |
Speed Of Back End Ports In Gbps | 4 x 12 Gb SAS Gbps |
Number Of Controllers Available In Storage System | 2 |
Supported Global Cache | Yes |
Total Configurable Cache Per Controller. | 48 GB |
Total No Of Drive Slots In The Storage System | 37 |
No Drive Slots Populated In The Storage System | 31 |
Capacity Of Single Drive Populated With The Storage System | 6 X 400 GB SSD 10 X 1.8 TB SAS 9 X 6 TB NL-SAS GB |
No Of Drive Slot Available For Scalability | The same array can be populated with 250 Drives. |
No Of Snap Shot Copies | 256 |
Remote Replication | Yes |
Synchronous Replocation Support | Yes |
Asynchronous Replication Support | Yes |
No Of Volume Supported | 1500 |
Three Way DR Capability | Yes |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | FC, NFSv3, NFSv4, NFSv4.1 CIFS (SMB 1), SMB 2, SMB 3.0, SMB 3.02, and SMB 3.1.1 FTP and SFTP iSCSI |
Hot Spare Available | Yes |
If Yes ,No Of Drives Per Hot Spare | 2 x 400 GB SSD 2 x 1.8 TB SAS 2 x 6 TB NL-SAS |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | Yes |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | Yes |
Network Switch | Not Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | NA |
Hardware Form Factor Of Network Switch | NA RU |
Number Of Network Switches Provided With Storage System | 2 X DS-6505 |
Number Of Active Ports In The Network Switch | 12 x 16 Gbps |
Operating System Platforms Supported | HP-UX,AIX,Windows 2008 R2,Windows Server 2012,Windows Server 2016,Oracle Linux, Oracle Solaris,Red Hat RHEL,SUSE SLES,Vmware ESXi6.0,5,5 |
Clustering Supported | Yes |
Deduplication | No |
Compression | No |
Operating Temp Range | Below 26C Degree C |
Storage Temp Range | Below 26C Degree C |
Operating Humidity (Rh) | NA % |
Storage Humidity (Rh) | NA % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | YES |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | 0.76 kVA Watt |
Max Power Consumption Of System | 0.76 kVA Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 5 Year |
Type Of Clustering | HOST BASED |