MIKRO 220 and 220 R are powerful,compact benchtop centrifuges forprocessing microlitre tubes of 0.2 mlto 2.0 ml. The refrigerated MIKRO 220 Ralso accommodates tubes up to a volumeof 50 ml.The MIKRO 220 and 220 R centrifugesare used in clinical laboratories as wellas in genetic research, virology andbacteriology. Capacity, performance andcooling of the MIKRO 220 R are specificallydesigned to meet the demands of samplepreparation for PCR applications..
Other Specifications Download Specification | |
---|---|
Centrifuge Design | Bench Top |
Centrifuge Type | Mini centrifuge |
Speed Mode | Variable Speed |
Rotor Configuration | Fixed Angle |
Interchangeable Rotors | YES |
Material Of Rotor | Aluminium |
Finish Of Rotor | Other |
Autoclavable Rotor At 121 Degree Celsius | YES |
Type Of Drive Motor | Brushless induction Motor |
Controler Type | Microprocessor Controlled |
Body Material | Die cast Aluminium |
Finish Of Body | Powder coated |
Base Material | Die cast aluminium |
Lid Type | Opaque |
Lid Material | Steel |
Lid Lock Detector | YES |
Emergency Lid Lock Release | YES |
Automatic Braking | YES |
Number Of Sample Tubes Testable Simultaneously | 24 |
Volume Of The Tube Testable | 1.5/2 ml |
Maximum Speed | 18000 RPM |
Minimum Speed | 100 RPM |
Speed Increment Step, If Variable Speed | 10 RPM |
Speed Control Accuracy Of Set Speed (+/-) | 10 RPM |
Maximum Relative Centrifugal Force(RCF) | 31514 x g |
Calibration | Automatic Calibration |
Temperature Control Method | Refrigerated |
If Refrigerated, Refrigeration System Free From CFC/HCFC | YES |
Temperature Setting Range(increment Step) | -20 TO 40 Degree Celcius |
Temperature Control Accuracy Of Set Temperature(+/-) | 1 Degree Celcius |
Acceleration Time (full Speed) | 9 sec |
Deceleration Time( Full Stop) | 9 sec |
Number Of Acceleration/deceleration Profiles In-built | 1 |
Timer Provided | YES |
Timer Setting (Increment Step) | 1 sec 99 min : 59 sec, continuous run, short cycle mode (impulse key) min |
Input Method/Interface | Digital Front Panel Without Glove mode |
Display Option/Output Read Out Option | Digital |
Type Of Data Logging Option | USB |
Rotor Imbalance Detection | YES |
Auto Cutoff | YES |
Pulse Mode | YES |
Programmable | YES |
Number Of Storable Programmes,If Programmable | 10 |
Input Voltage With Phase | 240 V |
Power Consumption | 850 W |
Input Current | 6 A |
Noise Level (maximum) | 54 db |
Ambient Operating Temperature | 24 Degree Celcius |
IP Rating Or Ingress Protection Rating | 21 |
External Dimension: Height | 313 mm |
External Dimension: Width | 330 mm |
External Dimension: Depth | 650 mm |
Weight Including Default Rotor | 44 kg |
Accessories And Spares Included In Standard Pack | 6X50ML ROTOR WITH ADAPTORS FOR 15ML TUBES |
Additional Safety Features | Lid locking and holding during rotor run l Emergency lid-lock release l Motor-overheating protection l Chamber-overheating protection (with the MIKRO 220 R) l Imbalance switch-off l Automatic rotor recognition l Lid dropping protection |
Free Service Available | YES |
Warranty On Rotor And Machine | 1 Years |
Supply Of Free Spare Parts Under Warranty | YES |
Annual Maintenance Contract(AMC) Available After Warranty | YES |
AMC Contract Period | 1 Years |
Product Code Available On Supplier Website | YES |
If Yes, Product Code | MICRO 220R |
Firm Certified To ISO9001:2008 Or Latest | YES |
Product Is CE Certified | YES |
If CE Certified, EN/IEC Directives | EN 55011 group 1, class B, EN 61000-3-2, EN 61000-3-3 |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | YES |
Test Report No. | 3654FS 1 1 F |
Test Report Date | 04 J nary 2 16 |
Name Of The Lab | MEDCERT |
Address Of The Lab | MEDCERT Zertifizierungs- und Prfungsgesellschaft fr die Medizin GmbH Pilatuspool 2 20355 Hamburg Germany |
Number Of Free Services, If Provided | 2 |