Keysight U1242C - 10,000 Count True RMS Handheld Digital Multimeter are the strong tools for technicians or industrial test engineers use to perform their work confidently and efficiently. Designed for handheld users working in various environments, IP 67 certified and capable to withstand up to 3-meter drop to suit harsh working environments. Up to 400 hours of battery life. Built-in LED flashlight, Allow to measure upto 1000VAC and DC Voltage, upto 10Amp. Ac and DC Current, upto 100 Megaohm Resistance, 10MHz Frequency,Temperature upto 1372 degree C. it has other feature like Null, Hold, Min and Max recording, Harmonic Ratio, Non-Contact Voltage detection, Analog Bar Graph, Low Impedance Mode, and differential temperature measurement. Warranty 3 years. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent. Delivery period is 60 days...
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.1 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 100 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 200 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 2000 points 500 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | -20 Degree C to +55 Degree C |
Operating Humidity (RH) | up to 80 Percent R.H. for temperature up to 30 degree C |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | 4x 1.5 V AA alkaline batteries (ANSI/NEDA 24A or IEC LR03), or 4x 1.5 V AA zinc chloride batteries (ANSI/NEDA 24D or IEC R03), or 4x 1.5 V AA lithium batteries (ANSI/NEDA 24-LF or IEC FR03) |
Total Voltage Of Battery | 6V |
Standard Accessories Supplied With The Equipment | Test leads (red and black), infrared (IR)-to-USB cable, four AAA batteries, Quick Start Guide, certificate of calibration. The offered Multimeter has IP67 Certified, Non-Contact Voltage Detection and Harmonic Ratio Measurement Capability. |
Dimensions (H X W X L) | 198 x 96 x 57 mm mm x mm x |
Weight | 545 Grams gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | U1242CMY57480006 |
Test Report Date | 18-DEC-2017 |
Name Of The Lab | Keysight Technologies Malaysia Sdn Bhd (463532-M) Bayan Lepas Free Industrial Zone 11900 Penang, Malaysia |
Warranty | 3 Year |