Keysight U1241C 10,000 Count 4-Digit True RMS Handheld Digital Multimeters Are The Strong Tools For Technicians Or Industrial Test Engineers Use To Perform Their Work Confidently And Efficiently. Designed For Handheld Users Working In Various Environments, IP 67 Certified And Capable To Withstand Up To 3-Meter 10 Feet Drop To Suit Harsh Working Environments. Up To 400 Hours Of Battery Life. Built-In LED Flashlight, Allow To Measure Upto 1000V AC And DC Voltage, 0.09 Percent DC Accuracy, Upto 10Amp. Ac And DC Current, Upto 100Megaohm Resistance, 10MHz Frequency, Temperature Upto 1372 Degree C. It Has Other Feature Like Null, Hold, Min And Max Recording. Warranty 3 Years. Refer Keysight Datasheet For Detailed Specifications. Delivery Period Is 60 Days. Prices Indicated Including GST @18 Percent..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.1 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 100 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | 20 C To 55 C |
Operating Humidity (RH) | Up To 80 R.H. For Temperature Up To 30 C |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 4x 1.5 V AA Alkaline Batteries (ANSI/NEDA 24A Or IEC LR03), Or 4x 1.5 V AA Zinc Chloride Batteries (ANSI/NEDA 24D Or IEC R03), Or 4x 1.5 V AA Lithium Batteries (ANSI/NEDA 24-LF Or IEC FR03) |
Total Voltage Of Battery | 6V |
Standard Accessories Supplied With The Equipment | 4-Digit Handheld Digital Multimeter, Test Leads (Red And Black), Four AAA Batteries, Quick Start Guide, Certificate Of Calibration |
Dimensions (H X W X L) | 198 X 96 X 57 Mm mm x mm x |
Weight | 545 Grams (With Batteries) gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | U1241CMY57330005 |
Test Report Date | 02-NOV-2017 |
Name Of The Lab | Keysight Technologies Malaysia Sdn Bhd (463532-M) Bayan Lepas Free Industrial Zone Malaysia |
Warranty | 3 Year |