MSSCREEN32 is designed for rapid screening of very large numbers of Clonal or PCR samples, the MultiSUB Screen horizontal gel unit has a 672 maximum sample capacity per gel. This allows loading and analysis of exactly seven 96-well format microtitre plates. The large gel run length of 32cm also allows resolution of samples over a long distance for separation of complex sample bands, such as in restriction fragment analysis. Buffer recirculation ports are included as standard to allow enhanced resolution over extended runs while loading guides enhance well visibility for easy sample loading.All MultiSUB Screen units now have the MS26-FC Flexicaster included. POWERPRO300 is best in class having 30 programs to save, the only power supply having 5 outputs, 300V, 700mA 150W..
Other Specifications Download Specification | |
---|---|
Types Of System | Horizontal Gel Electrophoresis system |
Applications | To separate charged molecules like DNA/RNA and proteins according to the size |
Series Of Electrophoresis | Large |
No. Of Maximum Samples Which Can Run | 672 Nos |
Body Material Of Electrophoresis Unit | Injection Moulded Construction |
Size Of Unit (WxLxH) | 28050090 mm |
Gel Tray Requirements | The tray should be UV proof and should have integrated fluorescent ruler which should get illuminated on exposure to UV lights for easy and safe calculation of the band movement |
Material Of Gel Tray | Acrylic, Casting with use of Flaxicaster provided as standard |
Width Of The Gel Tray | 26 cm |
Length Of The Gel Tray | 32 cm |
Thickness Of Combs And Colour Code | 1mm-white,1.5mm- Red,2mm-Blue |
All Combs Of Adjustable Height | Yes |
No. Of Wellcombs | 6 Nos |
Width Of Well,cm | 1 cm |
Length Of Well,cm | 26 cm |
Volume Of Gel,ml | NA ml |
Type Of Electrode | Gold Plated Platinum Electrodes |
The Base Buffer Volume,ml | 2000 ml |
Details Of Other Components Included | Tank, UV tray of 26x32, Lid with Buffer Recirculation Ports, Black and Red Electric Leads, Flaxicaster, Loading Guides, Cables |
Required Dye Chemicals | NA |
Specified Voltage For Dye Migration | 100 V |
Dye Migration Rate | 4 cm/hr |
Maxi.output Voltage Of Power Supply Unit | 300 V |
Output Current | 700 mA |
Ouput Wattage,W | 150 W |
Constant Voltage | Yes |
Constant Current | Yes |
Display | LCD display |
Control | Microprocessor controlled |
No. Of Electrode Terminal Ports | 10 Nos |
Alarm For Time Completion | Yes |
Timer Range Up To | 999 minutes |
Autostart After Power Breakdown | Yes |
Operating Voltage | 240 V |
Operating Temperature Range | 40 deg.C |
Power Unit Dimension (LxWxH) | 215335104 mm |
Weight Of Power Unit | 2.1 kg |
Warranty Period Of The System | 1 years |
Details Of Consumables To Be Supplied | NA |
Installation,commissioning And Training Part Of The Supply | Yes |