Keysight Technologies 33621A 120MHz Single Channel Function Generator-waveform generators with exclusive Trueform signal generation technology offer more capability, fidelity and flexibility than previous generation Direct Digital Synthesis DDS generators. Compatible with Keysight BenchVue software. Trueform technology offers Unmatched capabilities for generating a full range of signals for your most demanding measurements. Sine waves with 5x lower harmonic distortion for more pure signals. Pulses up to 100MHz with 1ps jitter for more precise timing.1GSa/s sampling rate for higher time resolution arbitrary waveforms.14-bit resolution with 1mVpp to 10Vpp amplitude for greater amplitude accuracy. 4 MSa/channel standard waveform memory, optional 64 MSa/channel for your longest waveforms. Standard 3 Year Warranty. Refer Keysight datasheet for detailed specifications. Standard Delivery period is 6 weeks. Prices indicated including GST @18 percent...
Other Specifications Download Specification | |
---|---|
Frequency Bandwidth (Sine Wave) | 10 mHz to 120 MHz |
No. Of Channels | 1 |
Standard Waveforms | Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset |
Band Width Of Arbitrary Waveform Generator | 10 mHz to 100 MHz |
Sample Rate Of Arbitrary Waveform Generator | 1000 Mega Samples/sec |
Record Length Of Arbitrary Waveform Generator | 128 Kilo Points |
Waveform Memory Of Arbitrary Waveform Generator | 4 Waveforms |
Vertical Resolution (Minimum) | 12 Bits |
Amplitude Range (at 50 Ohm Impedance) | 10 mV to 10 V pp |
Modulation | AM, FM, PM, FSK, Burst, PWM |
Interface | USB |
Display | Colour |
Standard Accessories (To Be Supplied) | Power Chord, USB Cable, Certificate of Calibration, Documentation CD |
Power Requirements | 230 V +/-10 AC, 50 Hz +/- 3 |
Operating Temperature Range | 230 V +/-10 AC, 50 Hz +/- 3 Degree C |
Operating Humidity (RH) | 0 to 55 Degree C Degree C % |
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. (Test Reports Are To Be Furnished When Demanded By Buyer)" | Yes |
Test Report No. | 33621AMY53802052 |
Test Report Date | 22-SEPT-2016 |
Name Of The Lab | Keysight Technologies Malaysia |
Warranty | 3 Years |