bpe make 3 kva online ups mf1103l8 for 120 min backup 65 ah smf battery x 8 nos. (bpe 3 kva online ups)(bpe make 3 kva online ups mf1103l8)

` 68,500.00

  • MRP: `79000.00

BPE Make 3 KVA Online UPS MF1103L8 for 120 Min Backup 65 AH SMF battery x 8 Nos. High Frequency and double conversion on-line technology.Fully digitalized microprocessor control.Wide input voltage rangeHighly Efficient upto 90High input power factor 0.99LCD displayCold startIGBT both Inverter Rectifier stage.Advanced battery managementAutomatic battery charge in UPS OFF modeShort circuit overload protection.EMI/RFI noise filter.Smart RS232 communications with monitoring softwareOptinoal SNMP Card slot.High reliability digital controlFull protection function.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V 1 sinewave,50Hz
  • Minimum VAH - 6240 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 3 KVA
Technology MOSFET-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V 1 sinewave,50Hz
Backup Time 120 Minutes
Minimum VAH 6240 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 2 %
Overall Efficiency 91 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. QVC/CE/LVD/2015-16/044
Type Test Certificate Date 30/11/2015
Name Of Lab QVC CERTIFICATION SERVICES PVT. LTD.
Address Of Lab QVC CERTIFICATION SERVICES PVT. LTD. 2-B CIVIL LINES, YUKTI BUSINESS CENTRE, NEAR OLD SESSION COURT AMBALA CITY 134003 HARYANA INDIA
Supply & Commissioning YES
Warranty 1 Years

Price Dekho Price Dekho Price List in india