Measuring technology-Spectrophotometer with reference beam technology,Wavelength range Vis-320-1100nm,UV190-320nm,Lamp type-Xenon flash lamp,Ambient light protection-Measurement with open shaft possible due to proprietary solution,Spectral bandwidth-4nm,Smart Screen Display-Resistive touch screen,Live ID System-2-D Barcode recognition for cell tests and reagent tests.Barcode contains lot,expiry,and calibration data.Data stored with each measurement,Cell size-16mmround cells,10,20,50mm,Cell recognition-Automatic Cell recognition by system sensors,Cell holder-Adaptor less cell holder for 16mm round and 10mm,20mm,50mm,rectangular.Cell holder is easily removable for cleaning purpose,Methods-Programmed methods of all Spectroquant cell and reagent tests more than 180test methods,99 user defined methods,20profiles for kinetics and absorbance scans each,Sample matrix check -Easy access through setting menu to perform instrument supported matrix check for each method, USB port available.
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | < 2 |
Type Of Detector | Photodiode |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | NA |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | 15-35 Degree C |
Operating Humidity (RH) | 30-80 % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | NA |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | NA |
Test Report No. | Na |
Test Report Date | NA |
Name Of The Lab | NA |
Warranty | 1 Year |